As appliances must discharge combustion products through ventilation hoods directly connected to the chimney
flue or to the outside (fig. 53).
If a hood cannot be installed, an electro-ventilator must be used which is applied to an external wall or to the
window in the room.
The electro-ventilator must have a capacity which ensures that the air in the kitchen is exchanged at least 3 to 5
times its volume (UNI-CIG 7129).
Components illustrated in fig. 53
A
: Opening for air entry
C
: hood for evacuating combustion products
E
: Electro-ventilator for evacuating combustion products.
Connection to the gas plant
)
Before installation, make sure that the local distribution conditions (gas nature and pressure) and
the hob adjustments are compatible. To do this, check the data on the product plate on the hob and
on this booklet.
Gas connection must be carried out in conformity with norms UNI-CIG 7129 e 7131. The hob must be
connected to the gas plant using rigid metallic pipes or continuous wall flexible stainless steel pipes which
conform to norm UNI-CIG 9891 with a maximum extension of 2 m.
Make sure that when using flexible pipes, these do not come into contact with moving or flattened parts.
Carry out the connection so that the appliance is not subjected to stress in any way.
The incoming gas connection pipe is threaded G½”.
No sealing is necessary for ISO R7 connections.
The supplied head washer is to be interposed with ISO R228 connections.
)
After connection, check that the connections hold using a soapy solution.
Connection to the mains
The apparatus must be connected to the mains checking that the voltage matches the value shown on the
characteristics plate and that the plant cable section can sustain the load also indicated on the plate.
Should the appliance be directly connected to the mains, an omni-polar switch, with a minimum opening of 3mm
between contacts, of the right size for the load and responding to the pertinent norms has to be interposed
between the appliance and the mains.
)
Do not use reducers, adapters or deviators for mains connection as they could overheat and burn.
)
Earthing the appliance is obligatory. The manufacturer will not be responsible for the non-
observance of this norm.
If the power supply cable is to be substituted, use a cable with the same characteristics as that supplied,
adapted to load and temperature
(type T90°C
) it must be requested from assistance. It is also necessary that
the end on the appliance side has a Yellow-Green earth wire 20mm longer than the others.
Consult the table below for the power supply cable dimensions
ADAPTATION TO DIFFERENT TYPES OF GAS
Should the hob need to be adapted to a gas different to the one it was intended for, the injectors have to be
replaced.
It there are no spare injectors supplied they can be obtained from Assistance.
The injectors are to be chosen according to the injector table.
Injectors can be identified by diameter expressed in hundredths of mm printed on the injector itself.
Hob type
Dimensions
Only with gas burners
3X0,50 mm
2
With one 1000W electric plate
3 X 0,75 mm
2
With one 1500W electric plate and two electric plates
3 X 1,5 mm
2
9
Summary of Contents for P6140FV
Page 2: ......
Page 15: ...Fig 1 1 Fig 2 1 2 Fig 3 1 Fig 4 1 2 Fig 6 Fig 5 Fig 7 1 2 1 1 13 ...
Page 16: ...Fig 10 1 2 4 3 Fig 11 1 2 4 3 Fig 12 1 2 4 3 Fig 8 Fig 9 14 ...
Page 19: ...Fig 29 3 2 1 Fig 30 3 2 1 Fig 31 3 2 1 17 ...
Page 21: ...Fig 39 Fig 40 Fig 41 Fig 42 19 ...
Page 22: ...Fig 43 Fig 44 Fig 45 Fig 46 Fig 47 Fig 48 Fig 49 20 ...
Page 23: ...Fig 50 Fig 51 Fig 52 Fig 53 Fig 54 21 ...
Page 24: ...Fig 55 Fig 56 Fig 57 22 ...
Page 25: ...23 ...
Page 26: ...24 ...
Page 27: ......
Page 28: ...CODE H01A393G ...