Page 6
Standard Equipment
The standard configuration of the PulsaCoil
Stainless is shown opposite. The Printed
Circuit Control Board (A.C.B.), mounted inside
the appliance, controls the production of the
domestic hot water. This is pre-wired to a
terminal strip where all electrical connections
terminate. The installer must fit components to
control the operation of the immersion heaters.
It is supplied with the following factory fitted
equipment:-
1. 3kW Off-Peak immersion heater
2. 3kW On-Peak boost immersion heater
3. Printed Circuit Board
4. Plate heat exchanger
5. Domestic hot water primary (plate heat
exchanger) pump
6. DHW temperature sensor
7. Incoming cold water sensor
8. Strainer and flow regulator
9. Screwed connection for a drain tap
10. Top up cistern complete with cold feed/
open vent pipework assembly is supplied
separately
11. Store sensor
Note
Both immersion heaters are low watts density
type with incaloy 825 sheaths and are specially
manufactured to suit thermal stores. It is
recommended that any replacements should
be obtained from Gledhill Spares.
The immersion heaters are fitted with control
thermostats and overheat thermostats.
Immersion heaters without these components
must not be fitted to the unit.
Optional Extra Equipment
•
In line scale inhibitor for mains water
services with hardness levels between 200
and 300ppm (mg/l) fitted but ready for
wiring by the installer to the suitable 230V
ac supply.
•
Polyphosphate scale inhibitor for fitting on
site by the installer.
•
Ballvalve/overflow connector for top up
cistern.
Figure 1.2
7
8
4
6
5
11
3
10
2
1
9
DESIGN
TECHNICAL DATA
Summary of Contents for PulsaCoil PCS 120
Page 25: ...Page 25 APPENDIX APPENDIX B ...