Supplied By www.heating spares.co Tel. 0161 620 6677
Page 7
ELECTR
AMA
TE
2000
27
Illustration above is the model EM 170
19
1
2
3
27
21
4
5
23
22
20
7
6
12
17
24
9 14 10 15 25
1.2 TECHNICAL DATA
Standard Equipment
The standard configuration of the ElectraMate
2000 is shown opposite. The Appliance Control
Board (A.C.B.), mounted inside the appliance,
controls the operation of the complete system.
It is supplied with the following factory fitted
equipment:-
1. Automatic air vent
2. Anti-vacuum valve
3. Primary mixing valve
4. Heating pump
5. PHE pump
6. PHE
7. DHW sensor
8. PHE return sensor
9. Hot water outlet
10. Mains cold water inlet
11. 90º angle isolating ballvalve (key/
screwdriver operated)
12. C A type backflow prevention valve -
discharging into a tundish
13. Filling pressure regulating valve
14. Heating flow
15. Heating return
16. 9kW electric flow boiler
17. Boiler pump
18. Pressure relief valve - discharging into
C A valve tundish
19. Expansion vessel
20. Store temperature sensor
21. Store overheat thermostat
22. Summer/winter switch
23. System pressure gauge
24. 3m x 10mm
2
electricity supply cable
25. Connection to expansion vessel
26. Danfoss TP5E Programmable Room Stat.
27. Boiler overheat thermostat
28. 100mm high installation pallet
Optional Equipment
*
Flexible connectors for quick
connection to first fix pipe installation.
*
2 x 20 litre expansion vessels
1.0 DESIGN
Summary of Contents for ElectraMate 2000
Page 38: ...Supplied By www heating spares co Tel 0161 620 6677 Page 38 APPENDIX D ...
Page 39: ...Supplied By www heating spares co Tel 0161 620 6677 Page 39 ELECTRAMATE 2000 ...
Page 40: ...Supplied By www heating spares co Tel 0161 620 6677 Page 40 ...
Page 41: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 42: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 43: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Page 44: ...Supplied By www heating spares co Tel 0161 620 6677 ...