background image

Page 54

TERMS AND C

ONDITIONS

1.  We only do business upon the Conditions which appear below and no other.  Unless we so agree in writing 
these Conditions shall apply in full to any supply of goods by us to the exclusion of any Conditions or terms 
sought to be imposed by any purchaser.  These Conditions of Sale and Warranty Terms override those which 
are contained on the Invoice Forms and all Sales are now subject to these Conditions of Sale and Warranty 
terms only.
2.  PRICE
Once an order or call off has been accepted the price will be held for three months but if delivery is extended 
beyond  that  period  at  the  customer’s  request,  then  we  reserve  the  right  to  amend  the  price  when 
necessary
.  The company reviews its pricing annually to adjust for changes in our cost base.  We reserve the 
right to alter prices at any time for severe movements in raw materials (mainly copper and steel).  If there is to 
be a change we will give customers at least four weeks notice but anything delivered after that date will be at 
the revised price.  An order may not be cancelled or varied after acceptance without the written consent of the 
company.  Such cancellation or variation shall be subject to such reasonable charges as may be appropriate.
3.  SPECIFICATION
The goods are supplied in accordance with the Specifications (if any) submitted to the Purchaser and any addi-
tions and alterations shall be the subject of an extra charge.  Any goods not so specified shall be in accordance 
with our printed literature or the literature of any of our component suppliers (subject to any modifications 
made since publication).  If we adopt any changes in construction or design of the goods, or in the specification 
printed in our literature, the Purchaser shall accept the goods so changed in fulfilment of the order.
4.  PAYMENT
The invoice price of goods shall be payable within 30 days of despatch by us of our invoice for the goods or such 
longer time as may be stated by our quotation or invoice.  If we receive payment in full on or before the due date 
we will allow an appropriate settlement discount except where we have quoted a special net price.  If payment 
is not received in full on or before the due date we shall be entitled in addition to the invoice price to:
(i)  payment of a sum equal to any increase in the copper price supplement applicable to the particular goods 
sold between the date of receipt of order and the date of receipt of payment in full; and 
(ii)  interest on any part of the invoice price unpaid after the due date at the rate of 3% per annum over the 
base rate for the time being of HSBC Bank plc.
5.  TIME
We give estimates of delivery dates in good faith and time of delivery is not nor shall be made of the essence 
of any contract nor shall we be liable for any loss or damage occasioned by delay in delivery.
6.  DELIVERY
We deliver free normally by our own vehicles within 25 miles of any of our manufacturing depots.  Delivery to 
any place more than 25 miles from one of our manufacturing depots may be subject to our quoted delivery 
charges.  We reserve the right to make delivery of goods contained in one order by more than one consignment 
and at different times.  Where a period is agreed for delivery and such period is not extended by our Agree-
ment, the Purchaser shall take delivery within that period.    If the Purchaser fails to take delivery, we shall be 
entitled at the Purchaser's risk and expense to store the goods at the Purchaser's premises or elsewhere and to 
demand payment as if they had been despatched.  Off loading at point of delivery shall be the responsibility 
of and be undertaken by the Purchaser.
7.  SHORTAGES OR DAMAGE
Goods must be inspected before signature of delivery note and any damage, shortage or discrepancy noted 
on the delivery note and the goods returned on the same vehicle.  The buyer must also give us immediate 
written notice of the damage, shortage or discrepancy so that we may prompt investigation.
8. RETURN OF GOODS
Goods may not be returned to the Company except by prior written permission of an authorised officer of the 
Company and such return shall be subject to payment by the Purchaser of handling and re-stocking charges, 
transport and all other costs incurred by the Company.
9. COMPANY LIABILITY
All our goods are made of the best materials from reputable manufacturers and where stated are manufac-
tured to the appropriate British or European Standard.  Complaints must be given to us immediately, before 
any action is taken, as responsibility cannot be accepted if repairs or renewals are attempted on site without 
our written authority.  

Defects  caused  by  corrosion  or  scale  deposits  are  not  covered  by  this  guarantee  save  as  expressly 
provided in paragraph (f) of this Condition 9.

Where we agree to rectify any defect, we reserve the right to undertake the work on our own premises.  
The following guarantee covers faulty materials and manufacture for the stated period, provided that:-
•  The unit has been installed in accordance with our installation and service instructions and all relevant codes 

of practice and regulations in force at the time of installation.

•  That all necessary inlet controls and safety valves have been fitted correctly.
•  It has only been used for the storage of potable water supplied from the public mains.
•  Where appropriate the unit has been regularly maintained as detailed in the installation and service 

instructions.

(a) Domestic and Commercial Open Vented Cylinders and Tanks.
The copper storage vessel is guaranteed for ten years and if it proves to be defective either in materials or 
workmanship, we will either repair or supply replacement at our option with the closest substitute in the case 
of any obsolete product to any address in Great Britain.
(i)    free of all charge during the first year after delivery by us.
(ii)  thereafter at a charge of one-tenth of the then current list price and any copper price supplement and 
delivery charge during the second year after delivery by us and increasing by a further one-tenth on the second 
and subsequent anniversary of delivery by us.
(b)  Domestic Mains Fed Products [Primary Stores]
The copper storage vessel is guaranteed for five years and if it or any integral pipework as part of the storage 
vessel assembly proves to be defective either in materials or workmanship, we reserve the right to either repair 
or supply replacements or the closest possible substitute in the case of any obsolete product and will collect 
and deliver to any address in England, Wales and Scotland (excluding all Scottish Islands).
(i) free of all charge during the first year after delivery by us.
(ii) thereafter at a charge of one-fifth of the then current list price or any copper price supplement and deliv-
ery charge during the second year after delivery by us increasing by a further one-fifth on the second and 
subsequent anniversary of delivery by us.

Gledhill

 (Water Storage) 

Ltd

(c)      Integrated  Boiler  and  Storage Vessel  Products  and 
Stand Alone Boilers
In  the  case  of  the  GulfStream  range  of  products  and  the    
Gledhill  boiler  range  of  products,    Gledhill  guarantees  the 
heat exchanger (boiler) for material and construction faults for 
two years and FURTHER we will meet the installer/contractors 
reasonable costs in removing and replacing any DEFECTIVE 
heat exchanger up to a MAXIMUM of one third of the extent 
of our liability in regard to the replacement product.
THE RESPONSIBILITY FOR THE EXECUTION OF THIS
GUARANTEE LIES WITH THE INSTALLER.
The guarantee becomes null and void if the appliance is used 
incorrectly,  or  in  the  event  of  proven  negligence  or  incor-
rectly  implemented  repairs  OR  FAILURE  TO  CARRY  OUT 
THE

   RECOMMENDED INSPECTION/MAINTENANCE.   The 

guarantee  also becomes null and void if changes are made to 
the appliance without our knowledge, or if the serial number 
on the appliance is removed or made illegible.
The  annual  service  must  be  carried  out  by  a  competent 
installer in accordance with the advice given by Gledhill and 
using Gledhill approved parts.
(d) Stainless Steel Unvented Cylinders
Gledhill guarantee the components including controls, valves 
and electrical parts for two years from the date of purchase.  IT 
SHOULD BE NOTED THAT THE FACTORY FITTED TEMPERATURE 
AND  PRESSURE  RELIEF VALVE  MUST  NOT  BE  REMOVED  OR 
ALTERED IN ANY WAY OR THE GUARANTEE WILL NOT BE VALID.  
GLEDHILL WILL NOT BE RESPONSIBLE FOR ANY CONSEQUEN-
TIAL LOSS OR DAMAGE HOWEVER IT IS CAUSED. 
The guarantee for the stainless steel vessel is for twenty five 
years  if  the  original  unit  is  returned  to  us  AND  PROVIDED 
THAT:
(i)  It  has  been  installed  as  per  the  Design,  Installation  & 
Servicing  Instructions,  relevant  standards,  regulations  and 
codes of practice.
(ii)  It has not been modified, other than by Gledhill.
(iii) It has not been subjected to wrong or improper use or 
left uncared for.
(iv) It has only been used for the storage of potable water.
(v)  It has not been subjected to frost damage.
(vi) The benchmark log book is completed after each annual 
service.
(vii) The unit has been serviced annually.
It should be noted that the guarantee does not cover:
- the effects of scale build up
- any labour charges associated with replacing the unit or  parts.
If the stainless steel vessel proves to be defective either in 
materials or workmanship we reserve the right to either repair 
or supply replacements or the closest possible substitute in 
the case of any obsolete product and will collect and deliver 
to  any  address  in  England,  Scotland  and  Wales  (excluding 
all islands):
(i) free of charge during the first year after delivery by us.
(ii)thereafter at a charge of one twenty fifth of the then cur-
rent list price during the second year after delivery by us and 
increasing by a further one twenty fifth on the second and 
subsequent anniversary of delivery by us.
ACTION IN THE EVENT OF FAILURE
If the Stainless Lite develops a leak we will ask for a deposit 
against the supply of a new one.  This will be refunded if the 
failure is within the terms of the warranty when it has been 
examined by us.
(e) Solar Panels and ancillary equipment
Gledhill provides a five year warranty for defects in the col-
lectors  (except  broken  glass  and  collector  accessories  eg 
metal edgings).  If the collector demonstrably fails to meet 
one of the requirements of the standard DIN 4757 part 3 we 
will replace it free of charge based on the date of invoice.  We 
can  not  be  responsible  for  damage  caused  by  mechanical 
stress and/or changes caused by weather related influences.  
The warranty  excludes minor surface damage that does not 
affect performance or malfunction due to improper assembly 
or installation.
Please note:
-  Installation must have been carried out by a licensed  special-

ized company (heating contractor or plumber) following the 
version of installation instructions in force.

- Gledhill or its representative was given the opportunity to 

check complaints on site immediately after any defect occurred.

-  Confirmation  exists  that  the  system  was  commissioned 

properly  and  that the system was checked and maintenance 
was performed annually by a specialised company licensed 
for this purpose.

AMD. MAY 2007

CONDITIONS OF SALE & WARRANTY TERMS

Summary of Contents for BMA 240 SP-SOL

Page 1: ...tic housing from an air source heat pump Air Source Heat Pumps Appliances These instructions also include wiring installation details for a special version of the BoilerMate HP appliance designed to work with the Mitsubishi PQFY VRF heat pump range BoilerMate Model Numbers BMA 180 HP PQFY BMA 210 HP PQFY BMA 240 HP PQFY Ecodan Air Source Heat Pump Model Number PUHZ W90VHA ...

Page 2: ...ority Building Control Department From 1st April 2005 this can be achieved via a Competent Person Self Certification Scheme as an option to notifying the Local Authority directly Similar arrangements will follow for Scotland and will apply in Northern Ireland from 1st January 06 CORGI operates a Self Certification Scheme for gas heating appliances These arrangements represent a change from the sit...

Page 3: ...e heat pump return to help protect the heat pump from any heating system contamination and provide an ongoing visual indication of the system water condition Interconnection Between Ecodan and BoilerMate A Class HP Aneightcoresignalcableisneededtoberunbetweenthe internal BoilerMate and the external Ecodan An 8 metre supply of this cable is provided with the BoilerMate if additional length is neede...

Page 4: ... with a local external isolator fitted in accordance with IEE wiring regulations Incoming Water Supply As the performance of hot and cold water systems is totally reliant on the incoming mains cold water supply check that the pressure will be a minimum of 2 bar at times of maximum simultaneous use and that the flow rate is a minimum of 30 litres minute For optimum performance this will need to be ...

Page 5: ...pliance must only be used with suitable heat pumps and is not suitable for use with any uncontrolled energy source such as solid fuel steam It should not be installed where the annual inspection is likely to be neglected The information in this manual is provided to assist generally in the selection of equipment The responsibility for the selection and specification of the equipment must however r...

Page 6: ...ump is not sufficient to meet the demands The controls are set to provide hot water priority ie if there is a demand at S3 any heating demands will be suspended until the store temperature reaches the point where S3 is satisfied All models are designed to heat the domestic hot water indirectly up to the maximum temperature possible with the heat pump and then boost the temperature by means of a3kW...

Page 7: ...s provided as part of the package Scale Protection The Building Regulations L1A New dwellings L1B Existingdwellingsandtherequirementsset out in the Domestic Heating Compliance Guide specify that where the mains water hardness exceeds 200ppm provision should be made to treatthefeedwatertowaterheatersandthehot water circuit of combination boilers to reduce the rate of accumulation of lime scale To c...

Page 8: ...pump flow 24 S4 sensor central heating flow boost 25 Electrical temperature boost assembly central heating Zone 1 only 26 S3 sensor hot water boost 27 Primary system manifold 28 Electrical temperature boost hot water only 29 Flow to hot water coil unvented system 30 Return from hot water coil unvented store 31 Domestic hot water outlet connection 32 Secondary domestic hot water return connection 3...

Page 9: ...erature boost assembly central heating Zone 1 only 26 S3 sensor hot water boost 27 Primary system manifold 28 Electricaltemperatureboost hotwateronly 29 Flow to hot water coil unvented system 30 Return from hot water coil unvented store 31 Domestic hot water outlet connection 32 Secondary domestic hot water return connection 33 Electrical control panel printed circuit boards and connection termina...

Page 10: ...ircuit Please note This is a diagramatic representation all pipework should enter through base of appliance All connections are 22mm Primary System Pipework Connections for BoilerMate A Class HP 180 Model Only Zone 1 flow Zone 1 return Water in return Water out flow A B Ecodan rear ...

Page 11: ... Either radiator or underfloor heating circuit Zone 2 Underfloor or other low temperature heating circuit Zone 1 flow Zone 2 flow Zone 1 return Zone 2 return Please note This is a diagramatic representation all pipework should enter through base of appliance All connections are 22mm Ecodan rear Water in return Water out flow A B ...

Page 12: ...bitor at extra cost In this case the aerial is fitted on the 22mm cold inlet and the scale inhibitor PCB is fitted in the electrical panel PCB area Figure 1 7 Figure 1 8 Primary system expansion vessel available as an optional extra at the time of order as part of the Primary Sealed System kit Unvented store expansion vessel supplied separately with the appliance Expansion Vessels Model Primary Ex...

Page 13: ...ontrol overheat safety thermostat temperature settings HW boost immersion heater S1 S2 safety sensors 3 P T valve 900 C CH boost immersion heater Control thermostat 5 650 C Overheat thermostat 4 850 C Control relief valve pressure set points Mains inlet pressure regulator 1 5 bar Expansion relief valve CW 3 0 bar Expansion relief valve CH 3 0 bar P T valve 4 0 bar Maximum hot water flow rate 25 35...

Page 14: ... normal way using the criteria set out in BS 6700 NHBC for storage appliances Electricity Supply One mains supply rated at 32A 230V 50Hz is required Minimum external fuse rating and the main supply cable ratings are given inTable 1 2 Technical Data section of this manual This appliance MUST BE EARTHED All external wiring to the appliance must be in accordance with the latest I E E Wiring Regulatio...

Page 15: ... are approximate and subject to a tolerance of 20mm in any direction Note All dimensions are shown in mm and are to the centre line of pipework gland 575 595 including the door clock 595 75 40 315 DHWS Expansion 440 Primary System Vent 300 545 180 Model Connection Details Dimensions Top DHWS Secondary Return Figure 1 9 575 595 including the door clock 440 Heat Pump Return 440 Heating Return Zone 1...

Page 16: ...Dimensions Bottom 415 Heating Flow Zone 1 Expansion Relief Valve Discharge DESIGN TECHNICAL DATA 210 240ModelConnectionDetails Dimensions Diagram opposite show the connection details and dimensions for the BoilerMate A Class HP DEM 210 240 models The BoilerMate A Class HP DEM units are supplied on an installation base to allow the pipe runs to connect to the appliance from any direction Itiseasier...

Page 17: ...ings and the requirements set out in the Domestic Heating Compliance Guide specify that where themainswaterhardnessexceeds200ppmprovisionshouldbemadetotreatthefeed water to water heaters and the hot water circuit of combination boilers to reduce the rate of accumulation of lime scale Tocomplywiththisrequirementthehardnessofthemainswatershouldbecheckedby theinstallerandifnecessarytheoptionalfactory...

Page 18: ...d that a small expansion vessel 0 25 0 5 litre is fitted after the pressure regulator to accommodate the pressure rise caused by the increase in temperature of the balanced cold water SH WHB SCV SCV WC BATH 22 22 15 15 WHB WC M DC DCV DC DCV To External Tap 25mm MDPE Incoming Supply WM or DWM SINK Discharge Pipe BoilerMate HP DEM Ground Level mains cold hot discharge balanced cold Location of opti...

Page 19: ...xed water outlets such as showers For this reason and because these are now no more expensive than a manual shower we strongly recommend the use of thermostatic showers with this appliance The shower head provided must also be suitable for mains pressure supplies If it is proposed to use a whole body or similar shower with a number of high flow pressure outlets please discuss with the Gledhill tec...

Page 20: ...designed and sized using the parameters for plastic pipework Selection Heat Pump Sizing General model selection guidance is given in Table 1 2 Technical Data Heat Pump Primary Circuit Theflowandreturnfromtheheatpumpmustrundirectlytotheconnectionsprovided on the BoilerMate A Class HP DEM appliance A Fernox Boiler Buddy is provided as part of the package and this must be fitted internally on the ret...

Page 21: ...volume allow 10 litres for the primary pipework coils within the appliance Sealed System Kit For The Central Heating System An optional sealed system kit as follows can be supplied with the BoilerMate A Class HP DEM Pressure gauge 0 4 bar Primary expansion vessel charged to 1 0 bar Size depends upon the model seeTable 1 1 WRAS approved primary system filling loop External Temperature Compensation ...

Page 22: ...itch button below the display for at least 5 seconds The Normal will change to Switch and will flash Once the problem has been resolved the appliance can be returned to normal operation by pressing the Switch button for at least 5 seconds Fault Condition Display Window If a fault occurs with the BoilerMate A Class HP DEM appliance the window will automatically display the fault condition The windo...

Page 23: ...d by ringing the Gledhill Technical Helpline 08449 310000 APPLIANCE CONTROL BOARD A C B Fuse T3 15L 250V 2 DIGIT ACB BOARD DISPLAY FLOW CHART Press S2 Press S2 Press S2 Press S2 Press S2 S2 S1 Press S1 Press S1 Press S1 Press S1 Appliance type Press S1 Press S1 Press S1 Press S1 Appliance type Press S1 Press S1 Press S1 Press S1 Fault code indicator block outs Press S1 Press S1 Press S1 Press S1 F...

Page 24: ...istance allowed for a straight length of 28mm pipe from a G temperature relief valve equates to 18m Subtract the resistance for 4 No 28 elbows at 1 0m each 4m Therefore the maximum permitted length equates to 14m As the actual length is 7m a 28mm copper pipe will be satisfactory In apartment flat situations the discharge pipes can be connected into a single pipe which is discharged at low level In...

Page 25: ...operate as quietly as practicable However some noise from pumps etc is inevitable in any heating system This will be most noticeable in cupboards formed on bulkheads or at the mid span of a suspended floor In these cases the situation can be improved by placing the appliance on a suitable sound deadening material i e carpet underlay or similar The appliance is very well insulated and no ventilatio...

Page 26: ...oftheseinstructions Beforeinstallationthesiterequirementsshould be checked and confirmed as acceptable The plastic cover and protective wrapping should be removed from the appliance and the installation base provided placed in position Theappliancecanbethenbeliftedintoposition inthecupboardontopofthebaseandthefront panelremovedbyunscrewingthe2screwsand liftingthedoorupandoutreadyforconnection of t...

Page 27: ... should be read in conjunction with this manual Runtheexternalwiringthroughtheserviceslot provided in the base of the appliance Make the connections as shown opposite on the terminal strip provided Theroomthermostatshouldbewiredasshown opposite The link in Z1RSL to Z1RSSL must be removed when the room thermostat is fitted The time and temperature controls for CH zone 2 should be wired as necessary...

Page 28: ...0mA 12 VDC 20mm Fuse A2 A1 HW B CH Z1 B 3kW Room thermostat call for Zone 1 Only Programmable Room thermostat call for Zone 2 Only Z1 RS E V S1 2 5 mm SID Silicone 2 3kW 3 WAY BUS BAR 2 5 mm SID Silicone 2 Remove link to wire room thermostat F1 14 11 12 R1 CC 3 1 2 4 ISSUE No 4 APPROVED DATE NOV 2007 GLEDHI DO NOT SCALE FROM THIS DRAWING COPYRIGHT OF THIS DRAWING IS RESERVED IT IS NOT TO BE REPROD...

Page 29: ...OUR LEGEND Black Orange Yellow White Red B Or Y Wh R S 3 S 4 S 5 S 6 Hot Water overheat sensors Hot Water Control sensor Zone 1 CH Flow Sensor Heat Pump Return sensor Outside Temperature Sensor Heat Pump Flow sensor S1 S2 SENSOR LEGEND S 7 3 Speed P2 P1 P3 R Bl Hot Water Valve V1 CH Zone 1 Valve V2 G Y Or Wh Bl J34 J5 J30 J31 J9 1 1 K 8 147MP_34 Wh Wh A1 B1 A5 A4 A3 A2 B2 B3 Br B 8 7 6 5 A B C D E...

Page 30: ...ected to the heat pump by the installer as shown If any additional length is required please use RS Components stock code 482 6036 25 metres and replace the entire length DO NOT JOINT Maximum length is 30 metres If using alternative cable to the above the individual cores must be a minimum of 0 5mm2 External Temperature Compensation Sensor Thisissuppliedconnectedto10metresofcable which is coiled a...

Page 31: ... corrosioninhibitor The heat pumpand external connecting pipework will also require protection against freezing For this reason a combined anti freeze and inhibitor product such as Fernox Alphi 11 must be used Thevolumes concentrationshouldbecalculatedinaccordancewiththemanufacturers instructions allowing 10 litres for the volume for the primary pipework coil in the BoilerMate A Class HP appliance...

Page 32: ... anchored 4 Do ensure that the functioning and control of the system is explained to the occupant and explain the need and importance of periodic servicing These Instructions should be replaced along with the component manufacturers instructions in the pocket provided on the appliance and the front panel refitted NOTE With sealed heating systems air is released from the water during the first few ...

Page 33: ...ddirectfrom Gledhill using the Speed Spares service or throughanyofthelargerplumbersmerchants specialist heating spares suppliers Help and advice is also available from the Technical Helpline on 08449 310000 However allcomponentsarereadilyaccessible and can be changed quickly and easily by the installer using common plumbing practice If it is necessary to replace any of the pumps fitted to the app...

Page 34: ...xpansion Vessel 24 Litre GT004 10 Primary Expansion Relief Valve and Pressure Gauge Comap XG154 11 Relay Wago 12 Contactors Heater elements Telemecanique XB014 13 Primary System Pressure Relief Valve XG169 14 Sensor S1 S2 Tasseron XB183 15 Sensor S4 S5 S6 Tasseron GT198 16 Central Heating Temperature Boost Immersion Element 17 Main Control Board Argus Vision XB442 18 External Temperature Compensat...

Page 35: ...hat the control overheat stat is replaced iii The motorised valve iv Checkthattheheatisbeingproducedbytheheatpumpandthepumpisrunning If the heat pump is running check replace the 100MA F1 fuse provided on the BoilerMate A Class HP DEM terminal strip to protect the main control board from a fault on the heat pump If for any reason heat is not being supplied to the appliance heating and or hot water...

Page 36: ...tallation die vorliegende Bedienungsanleitung und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage MANUEL D INSTALLATION Avant d installer le climatiseur lire attentivement ce manuel ainsi que le manuel d installation de l appareil intérieur pour une utilisation sûre et correcte English Deutsch Français For safe and correct use read this manual thoroughly before inst...

Page 37: ...pplied pipe work must be connected to the heat pump boiler by using QTY2 600mm 1 bore steel braided rubber flexible hose one for flow and one for return which are supplied with the unit Pipe work between the unit and the Hot water tank shall be minimum 22mm Provision shall be taken to avoid this pipe work freezing during winter months 4 Anti Vibration Connections flexible hose supplied loose 5 Sys...

Page 38: ...ories are improperly installed it may cause water leakage electric shock or fire Do not remodel the unit Consult an installer for repairs If alterations or repairs are not performed correctly it may cause water leakage electric shock or fire The user should never attempt to repair the unit or transfer it to another location If the unit is installed improperly it may cause water leakage electric sh...

Page 39: ...itch can severely damage the internal parts Keep the main power switch turned on during the operating period Before starting operation check that all panels guards and other protec tive parts are correctly installed Make sure not to get injured by touching rotating hot or high voltage parts Do not touch any switch with wet hands There may be a risk to get an electric shock Do not touch the refrige...

Page 40: ...such as a typhoon etc may directly blow to the air outlet Fig 2 3 Air outlet guide 3 Position the unit so that the outlet air can blow at right angle to the seasonal wind direction if possible Fig 2 4 Wind direction 2 4 NECESSARY SPACE TO INSTALL 2 4 1 When installing a single outdoor unit Refer to the last page Minimum dimensions are as follows unless Maximum dimensions are indicated Refer to the...

Page 41: ...iring size must comply with the applicable local and national codes 2 Power supply cables and the cables between Controller and Outdoor unit shall not be lighter than polychloroprene sheathed flexible cables Design 60245 IEC 57 3 Be sure to connect the cables between Controller and Outdoor unit directly to the units no intermediate connections are allowed Intermediate connections may result in com...

Page 42: ...ed below measure the insulation resistance again The insulation resistance drops due to the accumulation of refrigerant in the compressor The resistance will rise above 1 M after the compressor is warmed up for four hours The necessary time to warm up the compressor varies according to atmo spheric conditions and refrigerant accumulation If the refrigerant accumulates within the compressor the com...

Page 43: ...e 43 Positioning the Air Source Heat Pump Fig 2 5 Fig 2 6 Fig 2 7 Fig 2 8 Fig 2 9 Fig 2 10 Fig 2 11 Fig 2 12 Fig 2 13 Fig 2 14 Fig 2 15 Fig 2 16 Fig 2 17 mm ECODAN AIR SOURCE HEAT PUMP INSTALLATION MANUAL ...

Page 44: ...rliegende Bedienungsanleitung und die Installationsanleitung der Innenanlage gründlich durchlesen die Klimaanlage MANUEL D INSTALLATION Avant d installer le climatiseur lire attentivement ce manuel ainsi que le manuel d installation de l appareil intérieur pour une utilisation sûre et correcte English Deutsch Français For safe and correct use read this manual thoroughly before installing the unit ...

Page 45: ...ecorrect BoilerMate HP PQFY type appliance BMA 180 HP PQFY BMA 210 HP PQFY BMA 240 HP PQFY See below for the hydraulic and electrical connections See next page for full electrical schematic diagram See previous sections of this BoilerMate HP manual for all other details Hydraulic Layout Electrical Layout BoilerMate HP Mitsubishi PQFY Water Out Heat Exchanger Water In Flow from heat pump Return to ...

Page 46: ... mm SID Silicone 2 3kW 3 WAY BUS BAR 2 5 mm SID Silicone 2 Remove link to wire room thermostat D H W D H W U F H U F H U F C U F C Procon ACH1 DHW UFH UFC DHW UFH UFC PQFY Heatpump Terminals 2 core signal cable SELV Outside Temperature Sensor Sensor Select Com N O N C A2 A1 CC R1 3 1 2 4 ISSUE No 3 APPROVED DATE OCT 2007 GLEDHI DO NOT SCALE FROM THIS DRAWING COPYRIGHT OF THIS DRAWING IS RESERVED I...

Page 47: ...en Grey Green Yellow G Gr G Y WIRE COLOUR LEGEND Black Orange Yellow White Red B Or Y Wh R S 3 S 4 S 5 S 6 Hot Water overheat sensors Hot Water Control sensor Zone 1 CH Flow Sensor Heat Pump Return sensor Outside Temperature Sensor Heat Pump Flow sensor S1 S2 SENSOR LEGEND S 7 3 Speed P2 P1 P3 R Comfort Cooling Call SL C G Y Or Wh BL J34 J5 J30 J31 J9 1 147MP_34 Wh Wh CH2 CH ZONE 1 GITAL CLOCK 6 5...

Page 48: ... result in pumps or valves seizing and ultimate system failure The Boiler Buddy can be connected directly to 22 mm copper pipework using conventional pump connectors it is also compatible with 15 mm with the appropriate adapter It is not recommended for 28 mm systems as it will restrict the water flow Boiler Buddy can be installed vertically or horizontally The unit is designed to slot into the sp...

Page 49: ...e is an indication that the system has not been treated correctly with Fernox Protectors Restorers and cleansers Boiler Buddy has a transparent body casing so that the build up of contamination on the core can be observed in service It has been designed to be fitted where it can be inspected and removed for cleaning and should be installed in the central heating return line as close to the boiler ...

Page 50: ...fore removing the Boiler Buddy place a container underneath the pipework to retain any water that may drip 1 Isolate the Boiler Buddy from the system by simply closing the quarter turn valves on the pump service connector 2 Once the Boiler Buddy has been isolated it can be removed Undo the two 11 2 BSP union nuts Once these have been fully unscrewed the Boiler Buddy can be pulled out between the t...

Page 51: ...h This will guard against accidental opening of the clamp 15 Using two new fibre washers place the Boiler Buddy back into the pipework between the two pump servicing valves 16 Tighten the union nuts until finger tight after which use a spanner to tighten 1 8th of a turn or until secure CAUTION The body casing is a plastic part and will fail if excessive force is used 17 The servicing valves can be...

Page 52: ...Page 52 FERNOX alphi 11 product data ...

Page 53: ...Page 53 FERNOX alphi 11 product data ...

Page 54: ... Cylinders and Tanks The copper storage vessel is guaranteed for ten years and if it proves to be defective either in materials or workmanship we will either repair or supply replacement at our option with the closest substitute in the case of any obsolete product to any address in Great Britain i free of all charge during the first year after delivery by us ii thereafter at a charge of one tenth ...

Page 55: ...ract ii all other goods the subject to of any other contract between the Purchaser and us which at the time of payment of the full price of the goods sold under this contract have been delivered to the Purchaser but not paid for in full c until property in the goods supplied hereunder passes to the Purchaser in accordance with paragraph 2 above i the Purchaser shall hold the goods in a fiduciary c...

Page 56: ...Thecodeofpracticefortheinstallation commissioning servicingofcentralheatingsystems ...

Reviews: