background image

Glastender, Inc.  •  5400 North Michigan Road  •  Saginaw, MI  •  48604-9780  

800.748.0423  •  989.752.4275  •  Fax 800.838.0888 / 989.752.4444  •  www.glastender.com

10

W

iRing

 d

iagRaM

W

aRRanty

BLACK

BLACK

BLACK

BLACK

BLACK

TERMINAL BLOCK

RECIRC MOTOR

COMPRESSOR

CARBONATOR

SWITCH

RECIRC SWITCH

GREEN

RECEPTICAL

CONDENSER FAN

TEMPERATURE CONTROL

GREEN

115v/60hz 20 amp RECEPTICAL REQUIRED

CARBONATOR

TANK

SWITCH

CARBONATOR

MOTOR

AGITATOR MOTOR

M

M

M

WHITE

WHITE

WHITE

WHITE

RUN START

RELAY STARTER

COMMON

OVERLOAD

M

LABOR:  Glastender,  Inc.  warrants  all  products  to  be  free  of  defects  in 

material and workmanship. In established areas, a start-up and a 90-day 

labor warranty are included with glasswasher models GT-24 and GT-

30.  The  GT-18  series  glasswashers  include  a  90-day  labor  warranty. 

Self-contained refrigeration models, except beer line chillers, include a 

90-day labor warranty and a 5-year compressor warranty. Authorization 

for labor must be obtained from Glastender within the 90-day warranty 

period and prior to the service being performed.

PARTS: Within one year from date of installation, or 15 months from date 

of factory shipment, whichever occurs sooner, Glastender, Inc. will replace 

any part or assembly found defective under normal use and service. Field 

replacement parts include a warranty of 90 days from date of installation. 

A warranty claim form MUST accompany all returned defective parts or 

assemblies. This form MUST be completed in full. Failure to do so may 

result in delay or denial of credit. Any defective part or assembly must 

be returned to Glastender, Inc., Saginaw, Michigan, with all transporta-

tion and delivery charges prepaid. Warranty repairs or replacements will 

be shipped FOB factory in Saginaw, Michigan.

The warranty does not cover equipment subjected to accidents, freight 

damage, alterations, improper power and/or plumbing hookups, improp-

er chemical use, general misuse, or lack of routine required maintenance 

as determined by Glastender, Inc. 

No representative, distributor, dealer, or any other person is authorized 

to modify this warranty. This warranty replaces all other written or ver-

bal warranties.

NOTE:  Glastender,  Inc.’s  policy  of  constant  quality  improvement 

means  that  prices,  specifications,  and  policies  are  subject  to  change 

without notice. Questions regarding this warranty should be directed to 

Glastender’s Customer Service Representative.

03/08/05

Summary of Contents for LC84

Page 1: ...ichigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com Operation Manual and Parts Directory LC84 Conquest Post Mix Remote Soda Line Chiller 2006...

Page 2: ......

Page 3: ...Cleaning Hints 4 Water Bath Cleaning and Maintenance 4 Sanitizing Water Circuits 4 Sanitizing Syrup Circuits 4 Preventative Maintenance Schedule 5 Trouble shooting procedures Poor Carbonation 6 Bad T...

Page 4: ...ional 6 legs must be installed to the cabinet bottom If unit is installed on a countertop or shelf a the cabinet must be sealed to the countertop or shelf with an NSF listed silicon RTV applied around...

Page 5: ...standard equipment Before connecting water supply drain approximately two gallons of water from supply to flush out foreign matter It is recommended that a water filtering systems be installed to red...

Page 6: ...reely without spurting Adjust the syrup regulator to 50 P S I Adjust diet syrup regulator if used to 12 P S I Check all connections for leaks Insulate and tape all exposed refrigerated conduit lines A...

Page 7: ...nd pump deck Clean coils and inside of tank with soap or detergent and rinse with water Replace motor and pump deck Replace refrigeration deck Plug cord from refrigeration deck back into control box R...

Page 8: ...ice Weekly Dispensing Follow Standard Brixing Tower Brix Instructions Check Weekly Remote Cooler Wash With Mild Detergent And Wipe Dry Weekly System Review Pressure Gauges Pressures For Proper Setting...

Page 9: ...itch With switch in ON fully opened Incoming water supply to unit should be 3 8 I D minimums Be sure pump and pump motor are properly aligned and the clamp is tight Broken vanes in pump requiring pump...

Page 10: ...inks per minute Pull Down 6 9 hours operational Maximum Distance to Dispensers 150 ft 46 m Carbonator Integral cold carbonator Carbonator Pump 100 gph 378 lph Carbonator Motor 1 3 HP 25 kW Circulating...

Page 11: ...for ventilation and servicing Top front sides are one piece and are removable for servicing the compressor 1 625 Air Intake On Off Switch Compressor Area Under cover Exhaust Exhaust Exhaust Exhaust E...

Page 12: ...Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com Typical Installation Diagrams Typical Installation Using bag in box syrup system Typical Installat...

Page 13: ...hs from date of factory shipment whichever occurs sooner Glastender Inc will replace any part or assembly found defective under normal use and service Field replacement parts include a warranty of 90...

Page 14: ...5400 North Michigan Road Saginaw MI 48604 9780 800 748 0423 989 752 4275 Fax 800 838 0888 989 752 4444 www glastender com 11 LC84 Compressor and Related Parts 1 2 3 5 4 8 6 7 9 10 11 13 14 15 16 17 1...

Page 15: ...tion pump white set of 2 pieces 9 00 10 09000261 GT 031404 104 exterior power cord 20 00 11 09000412 GT 037112 Carbonator tank 115V 415 00 12 09000479 GT 034114 Relay compressor 20 00 09000480 GT 0312...

Page 16: ......

Reviews: