background image

ELECTRICAL WIRING AND OUTLET LOCATION 

SWITCH OFF THE ELECTRICAL  
SUPPLY TO THE CIRCUIT BEFORE  
BEGINNING.

 

 
Unit is designed to be installed in a lighting circuit 
with a dimmer switch. Pre-wire as shown or run 
new wire from the new dimmer switch, which is 
dedicated to just this unit’s operation. (120V), 14 
Guage AWM). 
 
The new outlet must be planned to the proper 
location behind the mirror so that the 90º plug 
from the unit installs easily without any tension 
on the cord. The extra cord should lay flat within 
the recess in the back of the unit. 
 
(See page 5 for Best Location of Outlet) 

USE WITH DIMMER SWITCH.

20 A GFCI

BREAKER

Dimmer Switch

Use Single Grounded Outlet

Service Wire 

Typical 
Vanity 
Height 

 
 Wall Switch

Mark the 

Mirror

 Surface Mount

Location

Service Wiring 

from 

dimmer switch 

to single outlet

This unit’s electrical connection from the 

breaker box to the  

dimmer switch to the wall outlet must be 

made by a Licensed Electrician in a manner 

that conforms to the National Electric 

Code.

4

Glasscrafters’ products work best with these 
 recommended dimmer switches: 
 

•Maestro® C•L® Dimmer from LUTRON®, MODEL # MACL -153M

 

http://www.lutron.com/TechnicalDocumentLibrary/369613a.pdf 

 

•DIVA® C•L ® Dimmer from LUTRON®, MODEL # DVCL -153P

 

http://www.lutron.com/TechnicalDocumentLibrary/369682.pdf 
 

It is recommended that the dimmer be within reach of your mirror so you can 
adjust the brightness. 
 
For on/off (no dimmer) operation, a standard wall switch may be substituted in 
place of the the dimmer.

 

ETL Certified: Conforms to UL 962

SPECIAL NOTE: NEVER use this 
 appliance with a three prong adapter.

Summary of Contents for Chelsea GCCHE-2430-FM

Page 1: ...ST 7 14 2020 GLASSCRAFTERS INC 11York Av West Caldwell NJ 07006 1 800 233 7362 F 1 888 233 7362 sales glasscraftersinc com To insure proper installation in complete compliance with your warranty we re...

Page 2: ...ufacturer 5 Never operate this appliance if it has a damaged cord if it is not working properly it if has been dropped or damaged A Safety Glasses should be worn at all times B Tape Measure C Level D...

Page 3: ...s Mirror Z Bracket Shim with Double Faced Tape tape side faces in to Bracket ILLUMINATED MIRROR SIZES PARTS FOR INSTALLATION 3 FRAMELESS 24 x 30 24 x 36 36 x36 May be installed Portrait or Landscape F...

Page 4: ...nity Height Wall Switch Mark the Mirror Surface Mount Location Service Wiring from dimmer switch to single outlet This unit s electrical connection from the breaker box to the dimmer switch to the wal...

Page 5: ...hould be at least 6 inches above the surface of any vanity sink TABLE 1 BASE LINE OF THE Z BRACKET FRAMELESS above unit base 30 high 26 75 36 high 32 75 Landscape format 24 high 20 75 FRAMED above uni...

Page 6: ...s 20 6 lbs 36 x 36 net weight of mirror is 13 2kgs 29 1 lbs Wall Z Bracket Wall Shim FRAMELESS MIRROR FRAMED MIRROR Unit Structure Frame Hanger Mirror Mirror Z Bracket Unit Structure Hanger Wall Screw...

Page 7: ...ircuit on Test the light and defogger unit using the dimmer switch Be sure the unit is off after each use Do not leave on for prolonged periods Never cover the mirror Clean with a soft dry cloth only...

Page 8: ...rn any merchandise under this warranty must be authorized in writing by GlassCrafters and must include prepaid shipping by the purchaser GLASSCRAFTERS INC 11York Av West Caldwell NJ 07006 1 800 233 73...