GLASCRAFT 20500-01 Operation Manuals Download Page 18

18  

GC-1041E

 

Dispense Tip Reference Chart

Part

Number

Orifice

LPA2-147-1525

0.015

                 1540

0.015

                 1825

0.018

                 1840

0.018

                 1850

0.018

                 2125

0.021

                 2140

0.021

                 2150

0.021

                 2325

0.023

                 2340

0.023

                 2350

0.023

                 2365

0.023

                 2640

0.026

                 2650

0.026

                 3125

0.031

                 3140

0.031

                 3150

0.031

                 3625

0.036

                 3640

0.036

                 3650

0.036

                 3840

0.038

                 3850

0.038

                 4325

0.043

                 4340

0.043

                 4350

0.043

                 5225

0.052

LPA2-147-5240 

0.052

5250

0.052

5265

0.052

6240

0.062

6250

0.062

6265

0.062

 7240

0.072

  7250

0.072

    Options

Spacer Seals

Use only Brown series C spacer seals with series B spray-tips, 

failure to do so may result in material clogging.

Series C Spacer Seals (Brown)

Short Version

Long Version

Use with tips LPA2-147-1525 

through LPA2-147-3850

Use with tips LPA2-147-4325 

through LPA2-147-7250

GC2335

16V976

23564-00

16V972

23572-00

16V973

LPA2-121G

16V974

LPA2-124S

16V975

 
 
 
 

 

1 : 

Tip Spacer Seal (Series C)

 

2: Spray-tip (Series B)

2

1

2

1

Summary of Contents for 20500-01

Page 1: ...ave these instructions Operation LPA2 IIG S External Mix Low Emission Dispense Gun For use with Polyester Resin and Gel Coat Models LPA2 100G LPA2 100S 20500 01 20500 02 Maximum fl uid working pressur...

Page 2: ...Grounding 6 Set Up Set up Instructions 7 Parts 12 Assembly Drawings 13 Pressure Relief Instructions 14 Maintenance Maintenance 15 Accessories 17 Technical Data Technical Data 19 Graco Ohio Standard W...

Page 3: ...when in the operating area of the equipment to help protect you from serious injury including eye injury inhalation of toxic fumes burns and hearing loss This equipment includes but is not limited to...

Page 4: ...ts Cleaning Solvent Hazard Created for CEDs Texture Sprayer May have use with other waterbase application equipment with plastic parts th can be damaged by certain solvents WARNING PRESSURIZED ALUMINU...

Page 5: ...ontact with isocyanates appropriate per sonal protective equipment including chemically impermeable gloves boots aprons and goggles is also required for everyone in the work area Some materials may be...

Page 6: ...ly a film will form on the surface and the ISO will begin to gel increasing in viscosity If used this partially cured ISO will reduce performance and the life of all wetted parts To prevent exposing I...

Page 7: ...st hose into SSP 160 slave pump and tighten 5 Reinsert catalyst delivery tube through gun han dle and carefully screw the delivery tube into the gun head Hand tighten only 6 With a box end wrench gent...

Page 8: ...S NOT suggest actual routing of hoses and tubing All hoses and tubing should be routed neatly and free of any moving components Air Manifold LPA2 II Gun MPB 209 Air Hose 20190 XX Catalyst Hose LPA2 II...

Page 9: ...260 00 Recirculation Hose tape together with green material hose Do Not insert the hoses in the material drum until the system has been flushed GAM 268 01 Pick Up Kit 20195 25 Material Hose Clear Tubi...

Page 10: ...10 GC 1041E Set Up ACV 100 Installation...

Page 11: ...GC 1041E 11 Set Up B 410 B 510 Installation...

Page 12: ...air Kits Part Number Description D 150 3 GUN SEAL KIT D 151 3 GUN MAINTENANCE KIT Standard Equipment Part Number Description LPA2 100G S LPA II DISPENSE GUN GC 1041 USER MANUAL LPA2 100G LPA2 100S Dis...

Page 13: ...GC 1041E 13 LPA 100G S Dispense Gun Assembly Drawings...

Page 14: ...gaged Daily Maintenance It is recommended that the following service be per formed on a daily basis 1 Inspect Gun valves needles shafts making sure that they are clean and free of over spray or foreig...

Page 15: ...old delivery tube with a 11 16 wrench 4 If optional fiberglass chopper is being used remove the chopper air hose with a 11 16 wrench Hold the air hose inlet fitting with a 9 16 wrench Tape a clean pol...

Page 16: ...16 GC 1041E Maintenance Material Needle Disassembly Procedure Catalyst Needle Disassembly Procedure Catalyst Needle assembly Procedure Material Needle assembly Procedure...

Page 17: ...GC 1041E 17 Dispense Tip Reference Chart Part Number Orifice 23047 J1 012 J2 014 J3 022 M1 012 M2 014 M3 022 N1 012 N2 014 N3 022 P1 012 P2 014 P3 022 Options...

Page 18: ...0 043 5225 0 052 LPA2 147 5240 0 052 5250 0 052 5265 0 052 6240 0 062 6250 0 062 6265 0 062 7240 0 072 7250 0 072 Options Spacer Seals Use only Brown series C spacer seals with series B spray tips fa...

Page 19: ...erature 100 F 38 C A Component Catalyst Inlet Size 1 4 18 NPS Male B Component Resin Inlet Size 1 4 18 NPS Male Sound Pressure 40 39 dB A Sound Power measured per ISO 94 16 2 56 2 dB A Dimensions 10 7...

Page 20: ...quential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two...

Reviews: