Symptom
Cause
Corrective ACtion
The flame effect will
not start.
Mains plug is not plugged in.
Low water level.
Low voltage connector not connected
properly. (Fig.4)
Check plug is connected to wall socket
correctly.
Check that the water tank is full and there is
water in the sump.
Check that the connectors are inserted
correctly. (Fig.4) Check the mains plug is
inserted correctly.
The flame effect is too
low.
Flame effect is set too low.
The Disc in the transducer might be
dirty.
The wire from the Transducer Unit is
sitting over the disc.
Increase level of flame by pressing
(button ‘E’) on your remote or receiver.
Clean the Disc with a soft brush. See
‘Maintenance.’ for a step by step procedure.
Direct the wire to the corner of the sump
and make sure it sits into the slot exiting the
sump - check the connection.
Unpleasant smell when unit
is used.
Dirty or stale water.
Using unfiltered tap water.
Clean the unit as described under chapter of
maintenance.
Use only decalcified/filtered tap water.
The flame effect has
too much smoke.
Flame effect setting is too high.
Decrease level of flame by pressing (button ‘D’)
on your remote or receiver. Give the flame
generator some time to adjust to the new
setting.
Product will not
operate. LED’s are
not on.
The product has no water
Refill the water tank.
8—Troubleshooting
Air filte
Lift the metal bed and place carefully on the table/worktop - see Fig. 3.
Gently slide the air filter upwards out of its plastic holder - see Fig. 12.
Gently rinse with water in the sink and dry with fabric towel before returning.
Replace the filter making sure that the coarse black filter is facing the front of the fire
Gently place the metalbed back into position.