3—General information
Only use decalcified/filtered water in this appliance.
This applliance is intended for table top, worktop and furniture type fittings
Always ensure that the appliance is sitting on a level surface.
Once installed, never move this appliance or lay on its back, without draining the water from sump and water tank.
If you intend not using the appliance for longer than 2 weeks, drain the water from sump and water tank and dry the
sump.
PLEASE NOTE:
Used in an environment where background noise is very low, it may be possible to hear a sound which
is related to the operation of the flame effect. This is normal and should not be a cause for concern.
Once installed, never move this appliance or lay on its back, without draining the water from sump and water tank.
The water tank, sump, sump lid, tank cap and air filters must be cleaned once every 2 weeks, particularly in hard
water areas.
If you intend not using the appliance for longer than 2 weeks, drain the water from sump and water tank and dry the
sump.
The sump and the water tank in this product are treated with a biocidal product, Silver Biocide. This conforms to the
latest relevant ISO standard.
Do not drink the water from the sump or from the water tank(s).
4—Installation instructions
This section describes how to install and set up your fire.
Before you start
Ensure that all packing items are removed (read any warning labels carefully) and retain all packing for possible future
use e.g. in the event of moving house or returning the appliance to your supplier.
Before connecting to the mains supply, check that the supply voltage is the same as that stated on the appliance.
Furniture type installlation
The model is intended to be used for furniture type installation - see Fig. 1 for product dimensions.
A minimum of 40cm clearance must be left between the metal bed and any shelf/enclosure above it, in order to
provide enough space for the flames/mist to form fully and not be obstructed.
There are slots at the base of the product that allows air to flow through, helping the mist evacuate effortlessly and
also to keep the electronic components cool.
The product needs ventilation from underneath or at the rear to operate effectively.
A minimum 200cm2 is required, for examples - see Fig. 1A.
Where the product is left in the centre of a room/hall, drafts or pedestrian traffic passing by the appliance can have
an impact on the performance of the flame. For these installations, we would recommend putting a 4 sided glass
surround, that sits on top of the table/worktop/shelf, around the outlet (metabed) - minimum size 33x33x10cm high.
To assemble the appliance into a ‘worktop’ (or similar type shelf), a rectangular hole is required to allow the product
to be dropped into place. Adding a recess allows the product to be ‘flush’/level with the worktop - see Fig. 2.
The metal bed is removable to allow access to controls and also to access the water tank, nozzle Lid, sump and
transducer - see Fig. 3. The 24V input connection is at the rear of the product - connect the jack from the power
supply unit to this input socket - see Fig. 4. A clearance hole (16-20mm) is required in furniture, to allow the lead
from the power supply unit to be fitted. Alternatively, the ventilation hole may be used. Insert the jack from the mains
cable to the power power supply unit (Do not Connect the Mains plug to a socket outlet until the appliance is ready
for operation). The product can be secured, by screw fixing through the base or at 2 sides - see Fig. 5 and 5a. (fixin
screws are not included).