background image

 

 

 

Installation

Preparing for installation

CAUTION:

 Always shut off the water supply before 

removing an existing faucet or replacing any part of a 
faucet. Open the faucet handle to relieve water pressure 
and ensure that the water is completely shut off.

HOMEDEPOT.COM/GLACIERBAY

Please contact 1-855-HD-GLACIER for further assistance.

       30 in.

Tub & Shower

8 in. Min.

      48 in. 

Shower Only

1 1/4 in. Diamter 

1 1/4 in. Diameter

       48 in. 

Tub & Shower

Refer to 
the step 2

       30 in. 

Shower Only

D

Installing the valve body and 
removing the plaster guard

 

Shut off the water supply to the tub and 
shower.

 

Verify that the hole sizes and positions of the 
holes in the wall are correct: 

 

The shower and tub spout outlet holes 
should be 1-1/4 in. diameter.

 

Refer to Step 2 for valve access hole 
dimensions.

 

The recommended valve depth to the 
finished wall is 2 in. min. to 3 in. max. 

 

Ensure that the valve body (D) cover is flush 
with the finished exterior surface of the wall. 
Position the valve body (D) correctly in the 
wall with the side marked "UP" pointing up. The 
8 in. minimum from the valve body (D) to the tub 
spout (J) is required for proper operation.   

The plaster guard (L) is positioned so that it is 
flush with the finished wall. This ensures that 
the valve will be at the correct position to accept 
the trim. The depth for the valve body (D) in wall 
is measured from the center of the shower 
outlet to the finished wall surface. The accepted 
depth distance is 2 in. to 3 in.. 

Unscrew the screws (K), and remove the plaster 
guard (L).

NOTE: 

Be sure to position the valve body (D) correctly in 

the wall, with the side marked "UP" facing upward. 

2 in. to 3 in.

Finished wall

6 in. dia.

D

L

L

K

Summary of Contents for 1001818631

Page 1: ...e our full line of products available for your home improvement needs Thank you for choosing Glacier Bay Questions problems missing parts Before returning to the store call Glacier Bay Customer Servic...

Page 2: ...the valve to the tub spout Tools and Hardware Required 3 Warranty LIMITED LIFETIME WARRANTY Glacier Bay products are manufactured with superior quality standards and workmanship and are backed by our...

Page 3: ...RED ADVANCED INSTALLATION Consult a plumber or professional before installing this product If you are replacing your plumbing valve please review the four common plumbing methods illustrated below COP...

Page 4: ...Flathead screwdriver S I L I C O N E Silicone sealant B IPS Key hole saw Flashlight C PEX COPPER Safety goggles Thread sealant tape Tube cutter Strap wrench Adjustable wrench Measuring tape Thermomet...

Page 5: ...ued 5 D CPVC COPPER Safety goggles Thread sealant tape Tube cutter Strap wrench Adjustable wrench Measuring tape Thermometer Phillips screwdriver Flathead screwdriver S I L I C O N E Silicone sealant...

Page 6: ...antity A 1 B Shower arm 1 C Shower head 1 D Valve body 1 E Escutcheon 1 F Handle 1 G Set screw 1 H 2 5mm hex wrench 1 Shower flange I Plug 1 J Tub spout 1 K Screw 2 L Plaster guard 1 M Escutcheon scre...

Page 7: ...iameter Refer to Step 2 for valve access hole dimensions The recommended valve depth to the finished wall is 2 in min to 3 in max Ensure that the valve body D cover is flush with the finished exterior...

Page 8: ...D 1 2 4 I 3b Installing the supply connections for soldering Before soldering remove the screw 11 inverter 12 sleeve 1 o ring 2 bonnet nut 3 cartridge 4 o ring 5 and stop valves 6 from the valve body...

Page 9: ...s and checking for leaks Place the handle F on the valve body D inverter and turn the handle F to the full on mixed position Turn on the hot and cold water supply lines and allow the water to flow fro...

Page 10: ...hten Wrap thread sealant tape around the pipe threads of the tub spout outlet 1 not included in a clockwise direction as shown Connect the tub spout outlet pipe the tub spout outlet pipe should projec...

Page 11: ...e cap in a clockwise direction NOTE The limiter on the valve can be set to allow partial or full access to hot water by limiting how far the handle can be turned to the hot side of the valve The limit...

Page 12: ...ust the red limit stop ring 1 in a counterclockwise direction and reinstall the red limit stop ring 1 onto the cartridge assembly 2 B Removing the red limit stop ring Remember the position of the red...

Page 13: ...acing down Then secure with the screw 3 Screw the sleeve 4 onto the valve body D NOTE Rotate the cartridge stem 1 clockwise to turn off the water before you install the handle 11 Installing the escutc...

Page 14: ...r flows continuously from the shower arm B Check for leaks Shut off the water at the faucet and supply lines 14 Care and Cleaning To clean wipe down with a damp cloth and dry with a towel Do not use a...

Page 15: ...auses below The pipe used between the valve and the tub spout is not 1 2 in IPS or the COPPER pipe is incorrect The valve is installed upside down There is a restriction between the valve and the tub...

Page 16: ...Part Number 10 Screw RP70560 11 Escutcheon RP80554 12 Escutcheon screw RP50190 13 Handle RP13469 14 Set screw RP50002 15 Index RP10055 16 Plug RP70365 17 Spout RP33073 Service Parts Specify Finish Ma...

Page 17: ...ssing parts Before returning to the store call Glacier Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD GLACIER 1 855 434 5224 HOMEDEPOT COM GLACIERBAY Retain this...

Page 18: ...sponibles para las necesidades de mejoras de tu hogar Gracias por elegir a Glacier Bay GRACIAS Problemas preguntas o piezas faltantes Antes de regresar a la tienda llama al servicio al cliente de Glac...

Page 19: ...ca o de la ba era Garant a GARANT A DE POR VIDA LIMITADA Los productos de Glacier Bay est n fabricados con normas y mano de obra de calidad superior y est n respaldados por nuestra garant a de por vid...

Page 20: ...ZADA Consulta a un plomero o profesional antes de instalar este producto Si est s cambiando tu v lvula de plomer a consulta los cuatro m todos comunes que aparecen m s abajo COBRE IPS PEX y CPVC Quita...

Page 21: ...beza plana S I L I C O N E Sellador de silicona Serrucho de punta Linterna C PEX COBRE Gafas de seguridad Cinta selladora para roscas Cortador de tuber as Llave de correa Llave ajustable Cinta m trica...

Page 22: ...fas de seguridad Cinta selladora para roscas Cortador de tuber as Llave de correa Llave ajustable Cinta m trica Term metro Destornillador Phillips Destornillador de cabeza plana S I L I C O N E Sellad...

Page 23: ...ectora 1 F Llave 1 G Tornillo de fijaci n 1 H Llave hexagonal de 2 5 mm 1 Brida de la ducha I Tap n 1 J Ca o de la ba era 1 Pre instalaci n continuaci n CONTENIDO DEL PAQUETE K Tornillo 2 L Protector...

Page 24: ...Consulta el paso 2 para las dimensiones del orificio de acceso de la v lvula La profundidad recomendada de la v lvula a la pared acabada es de un m nimo de 5 1 cm a un m ximo de 7 6 cm Aseg rate de qu...

Page 25: ...rpo de la v lvula D y el ca o de la ba era J NOTA Si no deseas instalar la salida de la ba era inserta el tap n I en la parte inferior del cuerpo de la v lvula D NOTA Si no deseas instalar la salida d...

Page 26: ...de suministro revertidas Rota el cartucho 5 180 de forma tal que H aparezca en la derecha Instala el cartucho asegur ndote de que la llave est bien enganchada con la ranura en el cuerpo de la v lvula...

Page 27: ...brazo B Coloca cinta selladora para roscas alrededor de las roscas de la tuber a del ca o de la ba era 1 no incluido en direcci n de las manillas del reloj tal como muestra el diagrama anterior Conec...

Page 28: ...ula D girando la tapa en el sentido de las manecillas del reloj NOTA El limitador de la v lvula puede configurarse para permitir acceso parcial o total al agua caliente al limitar hasta d nde puede gi...

Page 29: ...eada temperatura m xima del agua Para agua m s fr a ajusta el aro de retenci n del l mite rojo 1 hacia la derecha y vuelve a instalarlo 1 en el conjunto del cartucho 2 Para agua m s caliente ajusta el...

Page 30: ...3 Enrosca la funda 4 en el cuerpo de la v lvula D NOTA Rota el v stago del cartucho 1 hacia la derecha para cortar el suministro de agua antes de instalar la manija 11 C mo instalar la placa protecto...

Page 31: ...corra de forma continua desde el brazo de la ducha B Verifica que no haya filtraciones Cierra la llave de agua en el grifo y las l neas de suministro HACIA ARRIBA PARA LA DUCHA 31 Cuidado y limpieza P...

Page 32: ...o de la ba era no es de 1 2 plg Las tuber a IPS o de COBRE son incorrectas La v lvula est instalada al rev s Hay una restricci n entre la v lvula y el ca o de la ducha La distancia entre la v lvula y...

Page 33: ...N mero de Pieza 1 RP38046 2 Brazo de la ducha RP38047 3 Cabezal de la ducha RP38306 4 Aro t rico RP60101 5 Cartucho RP20075 6 Tuerca del bonete RP7043701 7 Aro t rico RP60091 8 Funda RP80553 9 Inverti...

Page 34: ...resar a la tienda llama al servicio al cliente de Glacier Bay de lunes a viernes entre 8 a m y 7 p m y los s bados entre 9 a m y 6 p m hora est ndar del Este 1 855 HD GLACIER 1 855 434 5224 HOMEDEPOT...