background image

5

 

 

GKD Technik Ltd

 

M3000004

 

Operator Display Guide continued...

 

Daily Checks

 

 

Before starting work, visually inspect the RCI sensors and wiring for damage, ensure that the RCI system is

 

in good working order and that the values for height, radius, slew position and load shown on the RCI are 
valid. Please refer to the User manual for daily check requirements.

 

 

System Start 

-

 Up

 

 

The 3RCI system should automatically start up when the ignition is turned on. Initially a green LED on the 
front panel will blink on and off to indicate that the system is booting up, and then the screen will power 
up. Once started up, the internal buzzer will sound continuously until the operator acknowledges the 

 

system by pressing the 

OK

 button. The operator will then need to input his 8 digit PTS number. Where 

the operator has a 6 digit Sentinel card number, it is suggested that two zeros are typed in first, followed 
by the 6 digit Sentinel number. The system will then go to the working screen shown on page 5.

 

 

Foreman Key

 

 

The RCI display incorporates a foreman key switch to the right of the display. When this key switch is in 
the 

Locked

 position, most of the buttons behind the 

[MENU]

 button will be greyed out and unavailable.   

To make them available, turn the foreman key switch to the 

unlocked

 position.

 

 

Lift Point Selection

 

 

Where multiple lift points are available, the lift point being used should be selected from the options

 

programmed into the RCI. The active lift point is shown on the main screen under the Height value (see 
item 5 on page 5). To change the active lift point, press the 

[MENU]

 button, and cycle through the 

 

available calibrated lift points using the bottom left button. 

 

Possible options are:

 

 

 

BP (Bucket Pin)

 

 

ALP (Auxiliary Lift Point)

 

 

QH (Quick Hitch)

 

 

TLJB (demountable tele jib)

 

 

Only those options enabled within the software will be available. Selecting the incorrect lift point will not 
compromise the safety of the system, but height, radius and load values may be inaccurate.

 

Summary of Contents for 3RCI

Page 1: ...M3000004 v1 2 Covering both Standard and SpaceGuard Systems V6 to V8 software only 3RCI Quick Start Guide...

Page 2: ...ntal changes by the operator 2 3 4 5 Display Touchscreen colour display which provides user information and control of the system Overload warning LED RED LED illuminates to show when the machine is i...

Page 3: ...Mode If the system is in dig mode this icon shows green and the motion cuts and alarms on overload are disabled the blue beacon is not illuminated Height Height of lift point from ground level road mo...

Page 4: ...is off then the system will not allow access to service menus or limit functions RCI Status Bar This bar fills from bottom to top and provides a visual reference of the relationship between the applie...

Page 5: ...t followed by the 6 digit Sentinel number The system will then go to the working screen shown on page 5 Foreman Key The RCI display incorporates a foreman key switch to the right of the display When t...

Page 6: ...he RCI screen will change the colour of the arrows representing available hydraulic services from green to red for any service that has been motion cut Any hydraulic service that will result in the lo...

Page 7: ...cant the RCI may restrict the movement of the stub boom back When the maximum boom angle is achieved in a potentially backwardly unstable condition the stub boom lift function will be motion cut and a...

Page 8: ...d to move the excavator to the desired clockwise limit position and press YES and then to the desired counter clockwise position and press YES again Slew limits will be set as captured from the turret...

Page 9: ...g on the operator main screen Operator Display Guide continued Current left Virtual wall distance Current right Virtual wall distance Distance from bucket pin to virtual wall Tandem Lift Duty In order...

Page 10: ...hat a problem is detected with the system the lift capacity is reduced to 700kg and an error message is displayed next to the MENU button indicating the nature of the error detected In the event that...

Reviews: