background image

-

2

-

12101

Programming

Walk Test

Note:  It is recommended that the detection LED be 
enabled during walk test to aid in set up.  The detection 
LED lights each time the MX25 detects your presence. 

Note: When you conduct a walk test, make sure that the 
front cover is in place. Do not conduct walk tests with 
the cover removed. 

The range of the detector increases without the protective 

front cover. Therefore the front cover must be fitted to 

establish the correct beam pattern. Use programming chart 

to adjust the range as necessary. Pan and tilt the lens 

module over the field of view to obtain the correct coverage 

area. 

Option

Switch Configuration

Reference

LED ON

Switch 1: On (Up)

Figure 10

LED OFF

Switch 1: Off (Down)

Figure 11

Pulse Count 1

Switch 2: Off (Down)

Figure 12

Pulse Count 2

Switch 2: On (Up)

Figure 13

10 Metre Range

Switch 3: Off (Down)
Switch 4: Off (Down)

Figure 14

15 Metre Range

Switch 3: Off (Down)
Switch 4: On (Up)

Figure 15

20 Metre Range

Switch 3: On (Up)
Switch 4: Off (Down)

Figure 16

25 Metre Range

Switch 3: On (Up)
Switch 4: On (Up)

Figure 17

Shaded settings are factory defaults

To change any of the MX25 settings, change the 

configuration of the programming switches (see Figure 9) 

as required.  switch 1 controls detection LED state, switch 2 

controls Pulse Count, and switches 3 and 4 control range.

Example: To change the range to 15 metres:

1. Set switch 3 to Off (down position).
2. Set switch 4 to On (up position).

Programming Options Definitions

Pulse Count

This is the number of times the unit has to detect on both of 

its sensors before signalling an output.

LED

LED Off – LED disabled.

LED On – LED signals a detection.

Programming Chart

Specifications

Detection Area

Programmable between 10 & 25 
metres.

Coverage

90 degrees detection angle, 25m x 
25m coverage max.

Adjustment

180 degree pan + 90 degree tilt.

Fresnel Lens

10 zones for each Pyro pair, which 
can be masked with curtain sliders 
and special masking tape (supplied).

Customised Optics

Double silicon shielded quad element 
eliminates 50,000 Lux of white light.

Outputs

Silent solid state magnetically 
immune.

No. 1

N / OPEN

Volt free relay signal contact 
24VAC/DC  @ 50mA with an integral 
25Ω resistor.
Alarm time 5 seconds.

No. 2

N / CLOSED

Volt free relay signal contact 
24VAC/DC  @ 50mA with an integral 
25Ω resistor.
Alarm time 5 seconds.

T

Tamper

Volt free, normally open switch output 
12VDC @ 25mA.

Tamper Switches

Front and rear tamper switches; case 
open and removal from wall.

Pulse Count

1 - 2.

Power Input

9 to 15 VDC.

Current

8mA (12V nominal).

Operating Temp.

-20 to +55 Centigrade
Conformal coated electronics for 
increased stability.

Housing

High impact ABS.

Protection Rating

IP 55.

Dimensions

84 x 106 x 72 mm.

Mounting Height

Variable – optimum height 3 metres.

CE Mark

GJD reserve the right to amend specifications without prior notice

GJD Manufacturing Limited

Unit 2 Birch Industrial Estate

Whittle Lane

Heywood

Lancashire

OL10 2SX

Sales: 

+44 (0) 1706 363 998

Technical: 

+44 (0) 1706 363 990

Fax: 

+44 (0) 1706 363 991

Email:

[email protected]

Web:

www.gjd.co.uk