background image

-

1

-

12101

MX25

GJD102 Quad PIR Movement Detector

Package Contents

Package Contains:

1 x MX25

1 x Allen Key

2 x 27mm wall plugs

2 x 27mm screws

3 x Tamper Feet

1 x Tamper Cup

1 x Installation manual

Introduction

The MX25 is an attractively styled, 25 metre Passive Infra-

red (PIR) detector, with advanced features such as dual 

tamper switches for case and wall-mount tamper detection, 

sensor mounted white-light filter and zone blanking using 

vertical curtain shutters and horizontal masking for precise 

area coverage.

5. When the detector is aligned, connected, and 

programmed to suit the installation, replace the 

front cover and lock in place.

The multifunction lens fitted to MX25 produces 5 long range 

beams and 5 medium to short range curtain PIR beams 

(see Figure 2). The PIR circuitry detects changes in heat 

and movement in the beam pattern; therefore items such as 

trees, shrubs, ponds, boiler flues, and animals should be 

considered when positioning the detector. 

Note: The PIR sensor is more sensitive to movement 
across the beams, and less sensitive to movement 
directly towards or away from the beams. 

The detector module is fitted with two sliding shutters to 

reduce the detection angle. 

When coverage exceeds the desired detection area, adjust 

the module as required and mask off any beams, either 

vertically or horizontally, to avoid unwanted detection. 

Use portions of the self-adhesive silver mask applied to the 

rear, smooth side of the lens as shown in Figure 2. Always 

replace the lens the correct way up to ensure exact beam 

pattern coverage (top of the lens is marked TOP).

When mounted at heights above 3 metres there could be a 

significant reduction in the range of detection and the target 

will have to move a greater distance within the field of view 

before an alarm is generated.

Quick Installation

1. Mount and connect the detector following the 

instructions given later in this manual. 

2. Configure programming switches as required 

referring to instructions given later in this manual.

3. Apply supply voltage to the unit. The blue detection 

LED flashes three times. 

4. Wait approximately 2 to 3 minutes to allow the 

detector to settle. 

Note: The front cover must be fitted when walk 
testing. 

The default settings are: 

Range: 25 meters

Pulse count: 1 (always set to 1 during walk rest)

Detection LED: On (recommend for set up process)

Mounting The Unit

Multibeam Alignment & Masking

Configuration

Mounting 

Height 

(Metres)

Tilt (°)

Max. 

Range

(Metres)

Reference

Multibeam 

(Optimum)

3

5

25

Figure 3

Pet Immunity *

1.5

-5

25

Figure 

4 & 5

Masking Configurations For Maximum Range

* Black area should be masked for pet alley applications up to 25 meters 
  (see figure 5).

During installation, protect the electronics against water, as 

trapped moisture can affect or damage the unit. 

1. Drill the wall to accept the two fixing screws, the 

cable entry, and the tamper cup (if used).

Note: We recommend using the tamper cup on 
uneven wall surfaces. 

2. Remove the cover assembly by loosening the 

locking screw using the allen key provided.  The 

cover hinges from the top and lifts out of the 

location slot.

3. Feed the cables into the cable entry and Screw the 

unit to the wall ensuring that the tamper pin is 

correctly located and that the tamper microswitch is 

closed.
Three spare tamper feet of different lengths are 

provided to aid installation. The tamper foot is a 

push fit and can be removed by carefully pulling it 

from the pin.

4. Connect the cables to the screw-terminal block on 

the back of the detector PCB (see Figure 1).

Figure 6 shows the pattern for the maximum range in the 

optimum position (see Figure 10).

Figures 7 and 8 illustrates alignment recommendations for 

when the detector is mounted close to a wall. 

The alignment shown in Figure 7 is not recommended. If 

the detector module is orientated at an angle of 90° to the 

perimeter, the mounting wall may cut off short and medium 

range beams. The long range beam will still detect an 

intruder, however the wall can cause false alarms when 

heated by sunlight. 

Figure 8 shows the recommended alignment. The detector 

module is orientated at a 55° angle to the perimeter. As a 

result, short and medium range beams are parallel to the 

perimeter, but the detection range along the perimeter is 

reduced.

Reviews: