22/06/2010 MT04_A30_B_VI110L_GIVI_ENG REV.B
18
32
Parameter 06
– ENABLE AND SET TIME FOR DEVICE SELF-SWITCHING OFF
It is possible to enable and program a stand-by time for an automatic switching
off of the device. Time is displayed in seconds and maximum programmable time
is 12 hours. To switch on again the device press the button ON/OFF.
Example of setting a time of 30 minutes (1800 seconds):
press
To enter the configuration and
select the parameter
P 0 6
press
Display will show “yes / no” to
indicate the set mode
n o
press
To enable the automatic switching
off
y e s
press
The first digit will blink
XXX.XX
select
and
To set the time
0 0 1 8 0
press
To confirm the value and return to
parameter selection.
P 0 6
press
To quit the configuration.
1 2 3 . 4 5
Parameter 07
- ENABLE RESET/PRESET OF INCREMENTAL QUOTA
If enabled it allows to reset/preset of quota in incremental counting mode.
Example of setting:
press
To enter the configuration and
select the parameter
P 0 7
press
The display will show “yes / no” to
indicate the set mode
n o
press
To enable the reset/preset of quota
y e s
press
To confirm the value and return to
parameter selection.
P 0 7
press
To quit the configuration
1 2 3 . 4 5