Troubleshooting:

Inverter shows error 61:

• 

Please ensure the correct BMS cable is used.

• 

Ensure the correct program on 05 is selected (LiB)

• 

Ensure the DIP switches are correct on the battery bank

4. 

Please switch on the inverter by its power button/switch and enter the programming 

menu by holding in the function key for 5 seconds. Once in the menu, use the arrow keys 

to navigate to program 05. Enter the program using the enter function key and change 

the setting with the arrow keys until LiB shows. Exit the menu. 

In 2-5 minutes the battery icon on the inverter will flash. 

This means that the inverter and battery has successfully established communication.

It is now safe to switch on the PV/Grid and output of the inverter.

3. 

Ensure the inverter is off and your Gird/PV and output is also switch off. 

Now it is safe to switch on the batteries. Switch on each battery by it individual breaker.

The following LED indicator may appear in new installation with multiple batteries. This is 

due to the batteries having different charge levels. 

This LED indicator will disappear after the battery bank has balanced out.

This indicator will not affect the system system performance.