47
EN
USER’S MANUAL
BR15
CALIBRATION OF THE WEIGHT
LF 1
DISPLAY
DESCRIPTION AND SEQUENCE OF USE
The calibration can be done with any weight, but the weight ca not be inferior to 1/100 of the maxi-
mum capacity and it must also never be exceeded.
•Press the key
to start the calibration of zero ( press
To exit the calibration and go back to
the menu LF1)
LF 1
CAL Z
150.00 kg
•Use
,
and
,
0 ~ 9
and then press
to introduce the weight with which the
calibration will be done. ( press the key
to exit the calibration and go back to the menu LF1)
150.00 kg
•Place the required weight on the scale as it is indicated in the display.
150.00 kg
•Once everything is steady, press the key
to calibrate it ( press the key ESC to exit the calibration
and go back to the menu LF1).
THE CALIBRATION IS GOING TO FINISH AND THE SCALE WILL GO VACK TO THE WEIGHING MODE AUTOMATICALLY.
CONFIGURATION
LF 2
DISPLAY
DESCRIPTION AND SEQUENCE OF USE
FIRST STEP
•DISPLAY OF THE INTERNAL COUNTING
262144
SECOND STEP
•POSSIBLE VALUES OF THE PARAMETERS
A: Metric system
0:NO
1: kg
2:T
3:g
1 0 0 0 0 1
B: American system
0:NO
1: lb
2:lb oz
C: other unities
0:NO
1: TW kg
2:HK kg
3:VISS
D: PCS
0:OFF
1: ON
A B C D E F
E: double range
0:OFF
1: multi interval
2:multi range
F: units of calibration
1:use metric
unities
2:use american unities
lb oz cannot be selected as unities of calibration.
The scale won’t let us continue up to the next step if there is a mistake during the programming.
THIRD STEP
•Use
,
and
,
0 ~ 9
and then press
to introduce THE MAXIMUM CAPACITY,
considering the number of decimal zeros to be used. Ex. 150.00kg = introduce 15000 if then selected
as decimal
d0.00
000000kg
FOURTH STEP
•Use the Keys
,
to change the position of the DECIMAL POINT.
dP 0.0
d 0.00
d 0.000
d 0.0000
0.00000
FIFTH STEP
•Use
to select the DIVISION:
diV 01, diV 02, diV 05, diV10, diV 20, diV 50
diV 01
After introducing the parameters LF2, the indicator will show the last configuration saved. All the
steps to follow must be completed, if they are not done the indicator will continue with the previous
configuration.
Proceed with the calibration of weight after LF2.