Bearings Replacement
Cod. 409748 Bearing
Rev. 00/0204
2
INDEX
SAFETY INSTRUCTIONS
1. Preparation
1.1. Variants of bearings’ box.
1.2. Necessary tools
1.3. Pieces and materials
1.4. Parts
1.5. Emptying the residual bath
1.6. Disassembling the covers
1.7. Disassembling the front panel of the
washing machine
1.8. Disassembling the outer drum front
1.9. Disassembling the drum
2. Machines without drainage. Action
2.1. Disassembling the bearings’ box
2.2. Changing the bearings
2.3. Preparing the outer drum
2.4. Assembling the bearings’ box
3. Machines with drainage. Action
3.1. Disassembling the bearings’ box
3.2. Changing the bearings
3.3. Preparing the back of the outer drum
3.4. Assembling the bearings’ box
4. Changing the seals
5. Assembly and verification
5.1. Assembling the drum
5.2. Assembling the outer drum front
5.3. Assembling the front panel of the
washing machine
5.4. Assembling the covers
5.5. Checking
the
machine
SAFETY INSTRUCTIONS
IMPORTANT
The operations described in these instructions are
restricted to the Authorised Service
WARNING!!
Before attempting any service or inspection of the
washing machine:
•
COMPLETELY
disconnect the machine from
the power source and check for accidental
reconnection. In LOGI CONTROL units, moving
the
ON
switch to the OFF position is not
sufficient.
•
Wait at least five minutes after disconnecting
the machine before beginning this operation.
Within the electrical circuit of the washer exists
high powered charges which can produce
important electrical shocks even after the
machine has been disconnected.
•
Close and mechanically interlock the water
supply valves and check that machine has
COMPLETELY
drained, parts have cooled
down and that no pieces are in movement
through inertia.
Failure to comply with this warning may result in