Bearings Replacement
Cod. 409748 Bearing
Rev. 00/0204
17
Tighten the lower area of the ring with the grip
pliers
(fig. 43).
If you have more than one plier,
place them in the lower area of the ring. Tighten
the joint screw of the ring.
5.3. Assembling the front panel of
the washing machine.
Fit the front panel with the side covers and fasten
it with the upper screws.
Fit the door lock device in the front panel. Fasten it
with screws.
Check that the latch of the door enters the lock
housing.
Fit the door joint into the rim corresponding to the
front panel. Fasten it with the spring clamp.
Fasten the lower part of the front panel with the
screws.
5.4. Assembling the covers.
Follow the steps in reverse of those for
disassembly (section 1.6).
Pay special attention to the arrangement of the
cables and connectors of the microprocessor
board.
5.5. Checking the machine.
Once
ALL
the washing machine covers are
mounted and fastened, check the operation and
water tightness of the washing machine.
WARNING!!
NEVER START THE MACHINE BEFORE
MOUNTING AND FASTENING ALL THE
WASHING MACHINE COVERS.
Steps to follow:
Check that the drainpipe outlet is placed and
fastened correctly.
Open the manual water supply valves.
Connect the electric supply of the washing
machine.
Load the washing machine with clothes.
Select a washing program. It is preferable to use a
program with a high temperature.
Execute the selected program. During the
execution of the washing cycle, check that no
alarms appear, which indicate a malfunction in the
machine, especially those related with the inverter
or motor.
fig. 43
Once finalized, disconnect the electric supply and
close the manual valves of the water inlets.
Take the front lower cover and the rear cover off.
Check that the base of the machine is dry and that
no bath loss occurs, especially in the joints of the
front panel of the outer drum and the door joint.
Check that no bath loss occurs, especially in the
joints of the bearings’ box and the back of the
outer drum or through the drainage tube
(machines with this type of assembly).
In the case of not observing any kind of anomaly,
put the covers on.
Open the manual valves and connect the electric
supply.
Remember that:
In LOGI Control machines, there is the possibility
of accelerating up the program (see Instruction
Manual, section 1.5).
In COIN machines, there is the possibility of using
the DEMO program (see Advanced Instruction
Manual, section 2.4).