Transport and location
22
Cod. 511485
Rev.07/0717
Fig. 2.6
Installing more than one washer
If the installation calls for more than one washer, align them with each other.
The minimum distance between adjacent machines and the user and maintenance areas (values
I
,
S
and
T of
Figure 2.6
) are specified on the table below.
Check the dimensions of the drain box and the drain pipe on the table below.
Positioning conditions
(Fig. 2.6)
I
DISTANCE BETWEEN MACHINES (MINIMUM)
mm (in)
700 (27.6)
S
WORKING AREA
mm (in)
1000 (39.4)
T
REAR MAINTENANCE AREA
mm (in)
750 (29.5)
A
DRAIN BOX
HS-6040; HS-6057
EH090; EH130
mm
(in)
300 x 300 x 250 (H)
(12 x 12 x 10 H)
HS-6110
EH255
mm
(in)
400 x 400 x 300 (H)
(16 x 16 x 12 H)
DRAIN PIPE
(
x1;
x2;
x3)
HS-6040; HS-6057
EH090; EH130
mm
(in)
150; 180; 200
(6; 7; 8)
HS-6110
EH255
mm
(in)
180; 250; 360
(7; 10; 14)