Installation

The room temperature controller is mounted in a 
58-mm flush-mounted box in accordance with 
DIN 49 073.
To install the room temperature controller, proceed 
as follows:
6. Remove housing cover:

Pull off setting knob.
Loosen cover screw.
Pull off cover.

Attention

Installation and mounting of electrical devices may 
only be carried out by a qualified electrician.
If the mounting and installation instructions are not 
complied with, a danger of fire and other dangers 
can arise.

Summary of Contents for temperature controller

Page 1: ...Bedienungsanleitung Raumtemperatur Regler 24 10 4 A mit ffner 0391...

Page 2: ......

Page 3: ...3 Inhalt Bedienungsanleitung Raumtemperatur Regler 24 10 4 A mit ffner...

Page 4: ...S len Werkst tten usw Installationsort Installieren Sie den Raumtemperatur Regler an ei ner Innenwand m glichst gegen ber der Heiz quelle Beachten Sie die empfohlene Montageh he ca 1 5 m ber dem Fu b...

Page 5: ...usst die Reglergenauigkeit nachteilig Vermeiden Sie daher direkte Sonnenein strahlung und die N he von w rmeabstrahlen den Ger ten Fernseher und Heizger ten Lampen Ka minen Heizungsrohren usw Auch ein...

Page 6: ...6 Installationsort...

Page 7: ...eglers gehen Sie bitte wie folgt vor 1 Geh usedeckel entfernen Einstellknopf abziehen Deckelschraube l sen Deckel abziehen Achtung Einbau und Montage elektrischer Ger te d rfen nur durch eine Elektrof...

Page 8: ...der UP Dose montieren Achtung Tragring immer auf Tapete montieren Bei Renovierungsarbeiten darf der Tragring nicht bertapeziert werden 4 Geh usedeckel mit Abdeckrahmen aufsetzen Geh usedeckel links o...

Page 9: ...urschwankungen da der Raumtem peratur Regler nicht ordnungsgem arbeiten kann Es ist kein Schutzleiteranschluss erforderlich da das Ger t schutzisoliert ist Achtung Fehler beim Anschluss k nnen zur Bes...

Page 10: ...10 Schaltbild...

Page 11: ...chreibung im Schaltbild L N Spannungsversorgung Anschluss f r Uhrsignal zur Temperatur absenkung Lastanschluss Heizen RF Widerstand f r thermische R ckf hrung TA Widerstand f r Nachtabsenkung der Raum...

Page 12: ...llen Werkseitig ist der Temperaturregler auf den maximalen Ein stellbereich von 5 C bis 30 C eingestellt Einstellvorgang So stellen Sie die Temperaturgrenzen ein in diesem Beispiel min 8 C max 23 C 1...

Page 13: ...f die obere Temperatur Grenze hier 23 C ein F hren Sie in eines der L cher des roten Rin ges einen spitzen Gegenstand z B Kugel schreiber ein Drehen Sie den roten Ring gegen den Uhrzeigersinn herum au...

Page 14: ...ch des blauen Ringes einen spitzen Gegenstand z B Kugelschreiber Drehen Sie den blauen Ring im Uhrzeigersinn herum auf 8 C Es gelten die inneren Zahlen der Skala 5 Einstellknopf aufsetzen Dabei muss d...

Page 15: ...umtemperatur abweichen Die Schaltpunktgenauigkeit ist erst nach 1 2 Stun den Betriebsdauer gegeben Zur schnellen Anfangs aufheizung und Abk rzung der Anfangsangleichung wird daher empfohlen die Einste...

Page 16: ...Skala zur Temperaturenstellung befindet sich auf der Abdeckung des Raumtemperatur Reglers und dient zur optischen Orientierung bei der Temperatur einstellung von min 5 C bis max 30 C ca 5 C 2 ca 10 C...

Page 17: ...ische Daten Temperaturbereich 5 C bis 30 C Nennspannung AC 24 V Nennstrom 10 4 A Schaltleistung ca 240 W Schalttemperaturdifferenz ca 0 5 K Nachtabsenkungen ca 4 K Leiterquerschnitt 1 bis 2 5 mm Massi...

Page 18: ...er t portofrei mit einer Fehlerbeschreibung an unsere zentrale Kunden dienststelle Gira Giersiepen GmbH Co KG Service Center Dahlienstra e 12 42477 Radevormwald Das CE Zeichen ist ein Freiverkehrs zei...

Page 19: ...19 Contents Operating instructions Room temperature controller 24 10 4 A with NC contact and On Off switch...

Page 20: ...s lecture halls workshops etc Installation site Install the room temperature controller on an inte rior wall and if possible directly across from the heat source Comply with the recommended installati...

Page 21: ...ther sources negatively influences con troller precision For this reason avoid direct sun light and objects which emit heat televisions heaters lamps chimney heating pipes etc Dimmers also generate he...

Page 22: ...22 Installation site...

Page 23: ...mperature controller proceed as follows 6 Remove housing cover Pull off setting knob Loosen cover screw Pull off cover Attention Installation and mounting of electrical devices may only be carried out...

Page 24: ...into flush mounted box with screws Attention Always mount support ring on wallpa per The support ring may not be wallpapered over when renovating 9 Set housing cover with cover frame in place Engage...

Page 25: ...ure fluctuations will result as the room temperature controller cannot work properly An earthed connection is not required as the device is double insulated Attention Errors during connecting can lead...

Page 26: ...26 Wiring schematic...

Page 27: ...m L N power supply connection for clock signal for temperature reduction heating load connection RF resistance for heat return TA resistance for night time heating reduction of room temperature LED LE...

Page 28: ...d with them The temperature controller is set to the maximum set ting range of 5 C to 30 C at the factory Setting procedure To set the temperature limits in this example min 8 C max 23 C 1 Turn the se...

Page 29: ...e red setting ring to the upper temper ature limit 23 C here Insert a pointy object e g pen into one of the holes of the red ring Rotate the red ring anti clockwise to 23 C The outer numbers of the sc...

Page 30: ...rt a pointy object e g pen into the hole of the blue ring Rotate the blue ring clockwise to 8 C The inner numbers of the scale apply here 5 Attach setting knob Here the indicator must be located appro...

Page 31: ...t time heating reduction switches off The switching point is not precise until after one to two hours of operation For quick initial heating and to shorten the initial adjustment we recommend set ting...

Page 32: ...temperature setting is found on the cover of the room temperature controller and is used for visual orientation when setting the temperature from min 5 C to max 30 C approx 5 C 2 approx 10 C 3 approx...

Page 33: ...range 5 C to 30 C Rated voltage 24 V AC Rated current 10 4 A Contact rating approx 240 W Switching temperature differential approx 0 5 K Night time heating reductions approx 4 K Conductor cross sectio...

Page 34: ...nd the device postage paid with an error description to our central customer service centre Gira Giersiepen GmbH Co KG Service Center Dahlienstra e 12 42477 Radevormwald The CE sign is a free trade ma...

Reviews: