All transformers switch off. 

Make a long press on the installation button. 
All transformers switch on to minimum brightness. 

If the installation button is still pressed, the light becomes brighter up to maximum 
brightness. 

5 Information for qualified electricians 

5.1 Fitting and electrical connection 

DANGER! 
Electrical shock when live parts are touched. 
Electrical shocks can be fatal. 
Before carrying out work on the device or load, disengage all the 
corresponding circuit breakers. Cover up live parts in the working environment. 

Fitting the transformer 

Ensure adequate installation space for heat dissipation. In critical cases, carry out temperature 
measurement. The housing temperature at the tc point (see transformer label) must not be 
exceeded. 
Do not fit in the vicinity of heat sources, e.g. lamps. 

Loosen screws (1) and remove terminal covers (3). 

Fasten transformer with screws through mounting holes (2). 

Connection instructions 

The transformer can be operated either with a DALI control unit or an installation button. 
Operation with a DALI control unit and and installation button at the same time is not possible. 

Figure 2 

Do not connect secondary cable with additional transformers (Figure 2). 

Do not lay secondary cable parallel to mains cable or transformer (Figure 2). 

Do not lay secondary cable on metal surfaces. 

Ensure that the control cable is of the appropriate type, cross-section and routing for the 
VDE specifications for 250 V cables, DALI interface has basic insulation. 

For reliable strain relief, use only cables of the same type on the primary side and on the 
secondary side. 

82575902 

13.05.2011 

3/7 

DALI Tronic transformer 105 W 

Summary of Contents for DALI Tronic Trafo 105 W

Page 1: ...the device or load These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 1 Fastening screws for terminal cover 2 Mounting holes 3 Te...

Page 2: ...ghtness value Adjusting brightness with installation button Light is switched on o Make a long press on the installation button Light becomes brighter or dimmer as far as the respective limit value i...

Page 3: ...must not be exceeded Do not fit in the vicinity of heat sources e g lamps o Loosen screws 1 and remove terminal covers 3 o Fasten transformer with screws through mounting holes 2 Connection instructi...

Page 4: ...V F 2 1 5mm2 H05VVH2 F 2 0 75mm2 H05VV F 2 2 5mm2 NYM J 3 1 5mm2 NYM J 3 1 5mm2 NYM O 2 1 5mm2 NYM O 2 1 5mm2 NYM J 3 2 5mm2 Figure 3 Stripping lengths o Strip connecting cables according to specifica...

Page 5: ...ng transformer with installation button Figure 5 Connection diagram with installation button i Illuminated installation buttons may only be connected if they have a separate N terminal i Connect all t...

Page 6: ...ower loss max 6 W Power factor 0 95 Output voltage AC 11 8 V eff Ambient temperature 20 50 C Housing temperature 75 C tc Protection rating IP 20 Safety class II Primary side connection Single stranded...

Page 7: ...ease submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward t...

Reviews: