background image

System 3000 

RF operating top unit

5

Insert-cover alignment

The device combination of insert and cover carries out an automatic insert-cover alignment as
soon as a cover is placed on an insert and the mains voltage is switched on.

Case 1: Insert and cover are brand new

After the insert-cover alignment, the device combination is functional in a standard configura-
tion.

Case 2: Insert is brand new and cover was already in operation

After the insert-cover alignment, the device combination is functional in a standard configura-
tion.

Case 3: Insert was already in operation and cover is brand new

After the insert-cover alignment, the device combination is functional in a standard configura-
tion.

Case 4: Insert and cover were already in operation in combination

After the insert-cover alignment, the device combination is functional. The device combination
performs its function according to its last configuration.

Case 5: Insert and cover were already in operation separately from one another

After the insert-cover alignment, the device combination is not functional. The insert-cover align-
ment identifies this case as a swapping of the covers, for example after renovating a room. The
insert-cover alignment reports an error via the status LED.

This device combination becomes functional again after programming with the ETS, a
master reset or resetting to factory settings.

Case 6: Insert is not supported by the cover

The insert-cover alignment reports an error via the status LED if the cover has been placed on
an insert not supported by the cover. The device combination is not functional.

5.1 Error message

The error reported by the insert-cover alignment is indicated by the status LED for 60 seconds.
Within these 60 seconds, the status LED flashes 3 times in pulses.

After an error has been detected during insert-cover alignment, the new assignment of a device
combination of insert and cover is only possible via the ETS. The device combination remains
without function until a new ETS is commissioned.

The 60-second signalling of the error is restarted each time the button is actuated.

The 2-gang device variant indicates the error message via the left status LED.

A firmware update is also possible in the event of an error.

6 / 12

32403802

10867449

10.11.2021

Summary of Contents for 5104 005

Page 1: ...w manual fully Danger of electric shock Always disconnect before carrying out work on the device or load In so doing take all the circuit breakers into account which support dangerous voltages to the...

Page 2: ...Device components Front view 1 channel Figure 1 and 2 channel Figure 2 Figure 1 Device components 1 channel Figure 2 Device components 2 channel 1 Rockers 2 Status LED 3 Cover frame 4 System 3000 inse...

Page 3: ...trans mitter 1 byte 2 bytes 3 bytes and 6 bytes brightness values temperatures calling up and saving of light scenes Operation in cabled KNX systems via media coupler see chapter Accessories Operatio...

Page 4: ...ration concept single area operation dual area operation Rocker function Each rocker can perform an indi vidual function Button function Two buttons above one another per form the same function Each b...

Page 5: ...ased Move Venetian blind Long press on button Stop or adjust Venetian blind Short press on button Set value e g brightness or temperature setpoint Short press on button Open scene Short press on butto...

Page 6: ...ce combination is not functional The insert cover align ment identifies this case as a swapping of the covers for example after renovating a room The insert cover alignment reports an error via the st...

Page 7: ...ard configuration The device combination does not transmit RF telegrams The ETS can reset the device to the delivery state with the Unload device command Status LED in the delivery state The status LE...

Page 8: ...netian blind or room temperature controller insert or 3 wire extension are mounted and connected properly see instructions of the relevant inserts The mains voltage has been switched off Fit the cover...

Page 9: ...channel Figure 6 Activating programming mode 2 channel Precondition The device is connected and ready for operation Activate programming mode Press the top right button and bottom right button simulta...

Page 10: ...mming is successfully completed the status LED carries out its parameterised function For Dimming The load must be connected before ETS commissioning Without a con nected load the ETS aborts the progr...

Page 11: ...r reset restores the basic device setting physical address 15 15 255 firmware re mains in place The device must then be recommissioned with the ETS During secure operation A master reset deactivates d...

Page 12: ...ld typ 100 m Receiver category 2 Ambient conditions Ambient temperature 5 45 C Storage transport temperature 25 70 C Relative humidity max 93 no condensation Gira Giersiepen GmbH Co KG Elektro Install...