Switching actuator / blind actuator 16 A Standard & Komfort

Press and hold down the programming button for > 5 s.
The programming LED flashes quickly.

The device performs a master reset, restarts and is ready for operation again after ap-
prox. 5 s.

Restoring the device to factory settings

Devices can be reset to factory settings with the Gira ETS Service App. This function uses the
firmware contained in the device that was active at the time of delivery (delivery state). Restor-
ing the factory settings causes the devices to lose their physical address and configuration.

6

Technical data

Ambient conditions
Ambient temperature

-5 ... +45 °C

Storage/transport temperature

-25 ... +70 °C

KNX
KNX medium

TP256

Commissioning mode

S-mode

Rated voltage KNX

DC 21 ... 32 V SELV

Current consumption KNX
Order no. 5023 00, 5028 00, 
5033 00, 5038 00

5 ... 18 mA

Order no. 5030 00, 5040 00

5 ... 24 mA

Outputs
Switching voltage

AC 250 V ~

Switching current AC1

16 A

Fluorescent lamps

16 AX

Current carrying capacity
Neighbouring outputs

Ʃ 20 A

Loads per output
Ohmic load

3000 W

Capacitive load

max. 16 A (140μ)

Motors

1380 VA

Switch-on current 200 μs

max. 800 A

Switch-on current 20 ms

max. 165 A

Lamp loads 230 V
Incandescent lamps

3000 W

HV halogen lamps

2500 W

HV-LED lamps

max. 400 W

LV halogen lamps with electronic transformers

1500 W

LV halogen lamps with inductive transformer

1200 VA

Fluorescent lamps T5/T8
uncompensated

1000 W

parallel compensated

1160 W (140 μF)

twin-lamp circuit

2300 W / 140 μF

8 / 9

82402612

23.09.2020

Summary of Contents for 5023 00

Page 1: ...utside the technical specifications Danger of electric shock Device is not suitable for disconnection from supply voltage Danger of electric shock on the SELV PELV installation Do not connect loads fo...

Page 2: ...out with the aid of the ETS version 5 7 3 and above Intended use Switching of electrical loads with potential free contacts Switching of electrically driven Venetian blinds roller shutters awnings and...

Page 3: ...us manual mode active Flashing temporary manual control active 8 LED ON relay outputs closed manual operation active 9 Button Short switch on adjust slats or stop Long Move hanging upwards 10 Button S...

Page 4: ...ey press the actuator returns automatically to bus operation Switching off temporary manual operation The device is in short term manual mode No button press for 5 s or Press 6 button briefly as many...

Page 5: ...gs The device is in continuous manual mode Press the ALL OFF button 7 Switching outputs All outputs switch off NO operating mode relay output opened NC op erating mode relay output closed Venetian bli...

Page 6: ...Mount device on DIN rail In secure operation The device certificate must be removed from the device and stored securely Connecting the device Figure 3 Device connection connection example Connect bus...

Page 7: ...program Only the system software of the device is still functional ETS diagnosis functions and pro gramming of the device are possible Manual operation is not possible Activating the safe state mode S...

Page 8: ...transport temperature 25 70 C KNX KNX medium TP256 Commissioning mode S mode Rated voltage KNX DC 21 32 V SELV Current consumption KNX Order no 5023 00 5028 00 5033 00 5038 00 5 18 mA Order no 5030 0...

Page 9: ...stranded without conductor sleeve 0 5 4 mm Finely stranded with conductor sleeve 0 5 2 5 mm Connection torque screw terminals max 0 8 Nm 7 Warranty The warranty is provided in accordance with statuto...

Reviews: