Figure 7
i
In the as-delivered state, Inputs 1 and 2 operate the Venetian blind output. Input 3 has no
function.
Function of Inputs 1 and 2 in the as-delivered state
Input
NO contact
Blind
1
Press briefly
Adjust slats Up / Stop
1
Press for a long time
Move up
2
Press briefly
Adjust slats Down / Stop
2
Press for a long time
Move down
4.2 Commissioning
Load the address and the application software
o
Switch on the bus voltage
o
Assign physical addresses and load application software into the device.
o
Note the physical address on the device label.
5 Appendix
5.1 Technical data
Window actuator flush-mounted, Order-No. 2164 00
Supply
Rated voltage
AC 230 / 240 V ~
Mains frequency
50 / 60 Hz
Switching voltage
AC 250 V ~
Ambient conditions
Ambient temperature
-5 ... +45 °C
Storage/transport temperature
-25 ... +70 °C
Venetian blind output
Contact type
µ
Switching current AC1
3 A
Minimum switching current AC
100 mA
Motors 230 V
600 VA
Motors 110 V
—
32572302
10499188 I00
20.05.2011
6/8