Gira 1039 00 Installation Instructions Manual Download Page 10

GIRA

Info

4-channel blind/shutter actuator 230 V~

Installation Instructions

4-channel blind/shutter actuator 230 V~

1/07

Page 10 of 10

Acceptance of guarantee

We accept the guarantee in accordance with the corresponding legal provisions.

Please return the unit postage paid to our central service department giving a brief description of the 
fault:

Gira
Giersiepen GmbH & Co. KG

Service Center

Dahlienstrasse 12
D-42477 Radevormwald

Gira
Giersiepen GmbH & Co. KG
Postfach 1220
D-42461 Radevormwald

Telefon: +49 / 21 95 / 602 - 0
Telefax: +49 / 21 95 / 602 - 339
Internet: www.gira.de

Summary of Contents for 1039 00

Page 1: ...run time detection with 230 V AC drives Direct control of blind shutter position Direct control of slat position Scene function Checkback of run status blind shutter position and slat position for bus...

Page 2: ...Fig 2 5 indicate the out put states Off output is off On output is on up or down Flashing slowly output in manual control mode Flashing fast output disabled in permanent manual control mode Modes of o...

Page 3: ...y for at least 5 s LED is on LEDs A1 are flashing permanent manual mode is activated Deactivating the permanent manual control mode The device is in the permanent manual control mode Press the key for...

Page 4: ...5 s The selected output A1 A4 is enabled The LEDs of the selected output are flashing slow ly Activate the bus mode deactivate the permanent manual control mode Information for qualified electricians...

Page 5: ...ation for qualified electricians The running time detection function is activated in the software The blinds shutters are not blocked Connect the bus line to the bus terminal Fig 3 Connect the mains v...

Page 6: ...the label Fig 7 7 Sliding on the protective cap To protect the bus lines against dangerous voltages at the connecting terminal slide on the protective cap Lead out the bus line at the rear of the devi...

Page 7: ...orehand The running times must be stored in undisturbed conditions i e without any control operations being performed and in the ab sence of wind snow and obstacles The automatic running time detectio...

Page 8: ...ge temperature 25 C 70 C Mounting width 72 mm 4 modules Weight approx 300 g Help in case of trouble Manual control with keypad not possible Cause 1 Manual control mode not programmed Program the devic...

Page 9: ...nic limit switches are being used Deactivate the automatic running time de tection Correct the electrical connection and re move the N conductor Blind shutter does not move to limit position po sition...

Page 10: ...ee in accordance with the corresponding legal provisions Please return the unit postage paid to our central service department giving a brief description of the fault Gira Giersiepen GmbH Co KG Servic...

Reviews: