Attention

This user manual is written and compiled in accordance with the council 
directive MDD93/42/EEC for medical devices and harmonized standards. 
In case of modifications and software upgrades, the information contained 
in this document is subject to change without notice.
The manufacturer makes no warranty of any kind with regard to this material, 
including, but not limited to the implied warranties of merchantability and fitness 
for a particular purpose. The manufacturer assumes no responsibility for any 
errors that may appear in this document, or for incidental or consequential 
damage in connection with the furnishing, performance or use of this material.
No part of this document may be photocopied, reproduced or translated to 
another language without prior written consent of the manufacturer.
The information contained in this document is subject to change without notice. 

Responsibility of the Manufacturer

The manufacturer only considers itself responsible for any effects on safety, 
reliability and performance of the equipment if:
Assembly operations, repairs are carried out by persons authorized by the 
manufacturer, and the device is used in accordance with the instructions for use.

 WARNING:

This device is not intended for treatment. The intended use is for detecting Fetal 
Heart Rate. If the fetal heart rate (FHR) result is distrustful, please use other 
methods such as stethoscope to verify immediately.

Warranty

The unit can not be repaired by users themselves. All services must be done 
by the engineers approved by manufacturer. We warrant that each product we 
sell you is free from defects in labor and materials and shall conform to its 
product specifications as defined in the user documentation. If the product 
doesn’t function as warranted during the warranty period, we will repair or
replace it without charge. Misuse, improper maintenance may void the warranty.

Using This Label Guide

This guide is designed to give key concepts on safety precautions.

 WARNING:

A WARNING label advises against certain actions or situations that could result 
in personal injury or death.

 CAUTION:

A CAUTION label advises against actions or situations that could damage 
equipment, produce inaccurate data, or invalidate a procedure.

Note

: A NOTE provides useful information regarding a function or procedure.

ENGLISH

Summary of Contents for Sonoline C 29480

Page 1: ...o ATTENTION The operators must carefully read and completely understand the present manual before using the product AVIS Les op rateurs doivent lire et bien comprendre ce manuel avant d utiliser le pr...

Page 2: ...operations repairs are carried out by persons authorized by the manufacturer and the device is used in accordance with the instructions for use WARNING This device is not intended for treatment The i...

Page 3: ...equipment Furthermore all configurations shall comply with the valid version of the system standard IEC60601 1 1 Everybody who connects additional equipment to the signal input connector or signal out...

Page 4: ...evice is not functioning properly or fails any of the above tests the device has to be repaired CAUTION The battery must be properly disposed The battery must be properly disposed according to local r...

Page 5: ...alculating unit LCD display control unit etc It has 3 work modes real time FHR display mode averaged FHR display mode and manual mode It also has audio output and can be connected with earphone or rec...

Page 6: ...26 Chapter 3 Outlook and Configuration Fig 3 1 Front Panel Fig 3 2 Rear Panel Start Stop Button Mode Button Power Button Probe LCD ENGLISH Speaker Battery Compartment...

Page 7: ...volume control button on Pocket Fetal Doppler The primary functions are as follows 3 2 1 Power Button Function Power on off Power on Push the button once Power off Push down the button and hold 3 sec...

Page 8: ...dio output and can be connected with earphone or recorder with audio input to record The socket terminal post or switch that connected with the headphones Accessory equipment connected to the analog a...

Page 9: ...al heart Apply a liberal amount of gel to the faceplate of probe place the faceplate of probe at the best position for detecting fetal heart Adjust the probe to obtain an optimum audio signal ideally...

Page 10: ...l heart rate bar graph on LCD indicates the strength of the fetal heart rate signals the shown fetal heart rate values and heartbeat waveform changes slowly 4 2 3 Manual Mode Mode 3 Press the start st...

Page 11: ...avoid falling off stress etc When the device is not used for a long time users are recommended to connect the plug of one probe to device socket and put the probe in the parking Then pack the device w...

Page 12: ...checks to ensure the fetal safety 4 5 Battery Status Indicator When it works normally the LCD screen displays the status of the battery as follows Battery power is full Battery power is not full Batt...

Page 13: ...Fig 4 2 Fig 4 2 Replacing Battery 2 Put two AA size batteries into the battery compartment as for the direction of battery please refer to the instruction inside the battery compartment at last close...

Page 14: ...wered equipment Anti electroshock Degree Type CF applied part Harmful Liquid Proof Degree Main unit Degrees of protection provided by enclosure IPXO Probe Prevent from water splashing degree of protec...

Page 15: ...signal power off automatically Battery Type Recommended Two pieces of 1 5 V DC battery SIZE AA LR6 Probe Nominal Frequency 2 0MHz Working Frequency 2 0 MHz 10 P 1 MPa Iob 20 mW cm2 Ispta 100 mW cm2 Ul...

Page 16: ...ree of dust and dirt clean exterior surface display screen included of the chassis with a dry soft cloth If necessary clean the chassis with a soft cloth soaked in a solution of soap or water and wipe...

Page 17: ...ice please solve them as below Problems Possible reasons Solutions ENGLISH Weak sound Noise Low sensitivity Volume is too low Power is low Did not daub the gel Probe is too near from the main unt Dist...

Page 18: ...more oxygen relatively the oxygen for fetus become less It is easy to arose symptoms such as fetus anoxia Testing the FHR at this time can display the healthy status for the fetus best The above thre...

Page 19: ...4 8 3 4 B a 40 9 6 6 8 T 20 4 8 1 B a 40 9 6 2 B w dB B dB V s r m s mV V n r m s mV 0 57 6 186 94 5 93 109 2 0 56 4 175 90 5 78 107 8 0 56 4 174 89 5 82 107 9 0 49 6 173 90 5 68 100 9 0 60 8 178 89...

Page 20: ...ity of the warranty GIMA will repair and or replace free of charge all the defected parts due to production reasons Labor costs and personnel traveling expenses and packaging not included All componen...

Page 21: ...122...

Page 22: ...123...

Reviews: