and gaining controlling, etc. The controlling system coordinates the 

operation of print controlling equipment, liquid crystal screen and keyboard 

driver, it is responsible for the profile print driver, controlling information 

demonstration, keyboard management and some other control.

3.2 Caution

3.2.1

 

Observe the status of the patients and the instrument momentarily.

3.2.2

  Use the patient cable only to connect the patient and instrument.

3.2.3

  Do not move the instrument and patient when the instrument working.

3.2.4

  Turn off the instrument after using it.

3.2.5

  Shut off the power supply, remove the patient cable gently without

 overexertion.

3.2.6

  Put away the instrument and its accessories for reuse.

3.3 Clinical restrictions

1.  If used with heart defibrillator or other stimulating equipment, the silver

 

and silver chloride chest electrode and heart electric conductance line

 

of our company can be chosen. If the defibrillating time surpassed 5,

 

there needs to use disposable chest electrode to resist burning the 

 

patients’ skin by metal electrode. Please don’t use with other electronic

 

stimulating equipment, if it has to, it needs conduction of professors.

2.  If other machine used connecting with device, the machines have to fit in

 

with the standard of IEC60601, because the sum total of leakage is able

 

to hurt patients, so the monitor of leakage current is responsible by the

 

inserting side.

 

4 TECHNICAL SPECIFICATIONS

1.  Display Format: LCD Display;

 

Battery Voltage Indication: three segments display.

2.  Power Requirements:

 

POWER ADAPTOR: Input AC: 100-240V, 50/60Hz;

 

Output DC: 12V;

 

DC: 7.4V  Lithium rechargeable battery.

3.  Input Power: ≤55VA.

4.  Sensitivity Setting: 5, 10, 20 (mm/mV),conversion deviation ≤5%.

5.  Fuse Standard: AC 250V/2A.

6.  Paper Speed: 25mm/s, 50mm/s±5%.

 

 

ENGLISH

Summary of Contents for ecg80a

Page 1: ...rs doivent lire et bien comprendre ce manuel avant d utiliser le produit ATENCI N Los operadores tienen que leer y entender completamente este manual antes de utilizar el producto M 33257 M Rev 0 12 1...

Page 2: ...to the respective chapters for details Please read the Manual very carefully before using this equipment These instructions describe the operating procedures to be followed strictly Failure to follow...

Page 3: ...4 TECHNICAL SPECIFICATIONS 7 5 ACCESSORIES 8 6 INSTALLATION 8 6 1 Sketch on each side and accessory 8 6 2 Electrode placement 9 6 3 Paper loading 11 7 OPERATING GUIDE 11 8 THE NOTICE OF THE BATTERY OP...

Page 4: ...arth According the Standard IEC60601 this device is belonged to internal electrical power source CF applied part it is applied for cardiac examination This device is safe and reliable Please select th...

Page 5: ...cture design transmission structure design and circuit design they produced ECG successfully after their deep research and reduplicate tests This equipment adopts the thermal recording mode the key po...

Page 6: ...ECG waveform using thermo sensitive printer at the same time waveforms also can be frozen at any time It has manual and automatic modes to be chosen and Chinese English operation interface it is easy...

Page 7: ...ulating equipment the silver and silver chloride chest electrode and heart electric conductance line of our company can be chosen If the defibrillating time surpassed 5 there needs to use disposable c...

Page 8: ...relevant regulation according to IEC60601 1 One lithium rechargeable battery DC 7 4V lithium rechargeable battery The battery can keep on working for more than four hours when it is fully charged ECG...

Page 9: ...29 Bottom View Back View 6 2 Electrode placement Advice Set the chest electrode first then the limb electrode 6 2 1 Elettrodo del petto AC Power Patient Cable Connector Battery Battery button ENGLISH...

Page 10: ...cal gel coating should be separated and the touching chest electrode may result in short circuit 6 2 2 Limb electrode Place the electrode on the hand and leg clean the positions around to which limb e...

Page 11: ...and protrudes 2cm in the top of the recording paper 7 OPERATING GUIDE 7 1 The instrument starts self checking after its turning on In the self checking process 7 2 The instrument will show the followi...

Page 12: ...it will show NORM when the leads collecting signals normally and OVER when the leads fall off or the collected signals too big and results in system saturation 3 Leads state indication When the leads...

Page 13: ...enu Interfaccia Inglese 1 Short menu Press to enter this interface Press to choose the relevant items and the item just turning then press button to set the information and then press to return 2 Cont...

Page 14: ...glish Chinese etc Demo ON OFF choose ON in demo when it dose not need to be actual checked 8 THE NOTICE OF THE BATTERY OPERATING 1 This device includes hermetical chargeable lithium battery which need...

Page 15: ...ot full The battery is only power supply and its power is exhausted The battery is charging 5 If the battery is full but the power of battery is exhausted within 10 minutes Please change new battery I...

Page 16: ...ths Inspect and maintain of Lead electrode 1 The state of leads can be checked by multimeter please check the leads according to following list If the resistance between electrode and relevant insert...

Page 17: ...e electrocircuit when the battery is over discharged 2 Check the AC power voltage The instrument has the function of protecting the electrocircuit when its overvoltage 3 Check AC interference check th...

Page 18: ...ectrodes 2 Verify the electrode attachment and patient cable wire performance 3 Check the cleaning of electrode and patient skin Daub enough ECG medical gel on the electrodes and patients 4 Keep the p...

Page 19: ...enough 5 The connection between patient cable and electrodes is not well 1 The batteries are drained 2 Patient moves 1 There is the filthy matter in the print head face 2 Paper problem 1 Checking ECG...

Page 20: ...acknowledgment shortcut menu Function Key Pause On Function Key System Menu Function Key Print Function Key Calibrate AC power is on no battery or full of battery The battery solely powered and the b...

Page 21: ...s product meets high qualitative standards both as regards the material and the production The warranty is valid for 12 months from the date of supply of GIMA During the period of validity of the warr...

Reviews: