The GIMA bipolar cables are devices used with bipolar electro-surgery devices. The cables are made of 

light and flexible silicone, they are 3 meters long and can be sterilized in an autoclave up to 135°. 

They have a universal connection that makes them easy to use with other GIMA devices and with most 

of the electric scalpels produced in Europe. 

INFORMATION 

The product is designed to be used only by qualified doctors, specialized in electro-surgery techniques 

and the maintenance of this type of product. 

The incorrect use or poor or inappropriate maintenance can make the product deteriorate quickly. 

These products can cause injuries if not used correctly! 

Do not put in contact with devices that are not insulated!

The electric scalpels used together with these cables will destroy tissues and are extremely 

dangerous if used incorrectly.

DESCRIPTION/INTENDED USE

These devices are reusable and are supplied non-sterile. Process through cleaning and sterilization prior 

to initial use.

Before using the device make sure the cables are fully compatible with the electro-surgical devices. 

Connect the connectors to the chosen surgical device and then the feeding device and verify that the 

connections are correct and that no metallic parts are left exposed. Do not bending the cable or fix it in 

any way with clips or similar devices that could damage its function¬ality.

REUSE

We guarantee our products to withstand a minimum of 20 sterilization cycles when sterilized in accord-

ance with the validated instructions contained herein. Care in use and handling can extend useful life.

CONTRAINDICATIONS

These devices should never be used when:

• There is visible evidence of damage to the exterior of the device such as cracked plastic or connector

damage.

• These devices fail the inspection described herein.

• In the presence of flammable gases, liquids, and/or oxygen enriched environments.

SAFETY TIPS

• Use lowest possible power setting on electrosurgical unit capable of achieving desired surgical effect.

• Never allow the cables connected to these devices to be in contact with skin of the patient or operator

during electrosurgical activations.

• Do not permit the cables connected to these devices to be parallel and in close proximity to the leads

of other electrical devices.

• Always place unused electrosurgical accessories in a safe insulated location such as a holster when

not in use.

Summary of Contents for 30617

Page 1: ... ATTENZIONE Gli operatori devono leggere e capire completamente questo manuale prima di utilizzare il prodotto ATTENTION The operators must carefully read and completely understand the present manual before using the product AVIS Les opérateurs doivent lire et bien comprendre ce manuel avant d utiliser le produit ACHTUNG Die Bediener müssen vorher dieses Handbuch gelesen und verstanden haben bevor...

Page 2: ...devices Connect the connectors to the chosen surgical device and then the feeding device and verify that the connections are correct and that no metallic parts are left exposed Do not bending the cable or fix it in any way with clips or similar devices that could damage its function ality REUSE We guarantee our products to withstand a minimum of 20 sterilization cycles when sterilized in accord an...

Page 3: ...ervical brush to clean smoke tube Do not overlap instruments in sterilization tray Do not soak coated instruments in CIDEX or other caustic cold sterilization solutions Do not use bleach Do not place coated instruments in ultrasonic cleaner STERILIZATION Wrap each pair of instrument separately or place in a container so as to prevent instrument from contact ing each other or other instruments Stea...

Page 4: ...the warranty GIMA will repair and or replace free of charge all the defected parts due to production reasons Labor costs and personnel traveling expenses and packaging not included All components subject to wear are not included in the warranty The repair or replacement performed during the warranty period shall not extend the warranty The warranty is void in the following cases repairs performed ...

Reviews: