1.  Before measuring, the thermometer shall be stabilized at least 30min under operating 

condition.

2.  Please keep your ear canal clear, if not, the measuring result shall be inaccurate.

3.  The symbol ‘   ’ on the LCD shows you can measure in the ear;

4.  The time between each reading should be not less than 12 Seconds otherwise there is not 

any change on the LCD. 

5.  Please don’t scratch the probe lens, if not the thermometer shall lose the efficacy;

6.  If the LCD no changes under pressing any button, please take the battery out and put in 

again.

7.  Please don’t use the thermometer if your ear canal has been inflammation.

8.  Do not expose this thermometer to electric shock. 

9.  Do not expose the thermometer to sunlight or to water. 

10. Do not modify this device without authorization of the manufacturer. 

11. Do not use near strong electromagnetic fields, i.e. Keep it away from any radio systems 

and mobile phones. 

12. This device must always be kept in a clean, dry area. 

13. 

 Degree of protection against electric shock is Type BF applied part.

14. 

 The disposal of battery and device shall comply with the local environment requirements

15. This device include small parts, don’t inhale or swallow it. 

16. Do not apply a strong shock to, drop, step on, or vibrate the main unit.

How to use

Measuring human body temperature in the Ear Canal. 

1. Press the ‘on/recall’ button to turn on the thermometer, 

a beep sound is heard and the LCD displays as Fig. A in 

one second.

  When the LCD displays as Fig. B, now ready to measure.

2. Straighten the ear canal by pulling the outer ear up and 

back to give a clear view of the eardrum.

  - For children under 1 year, Pull the ear straight back.

  - For children ages 1 year to adult, Pull the ear up and 

back. (Caution: Many pediatricians suggest use of ear 

thermometers for children older than 6 months.)

3. While pulling the outer ear, insert the probe snugly into 

the ear canal (best to insert deep), press the ‘scan’ button.

Release it when you hear a beep sound. A beep indicates 

measurement is complete.

  Remove the thermometer from the ear. The display show 

the measure temperature.

4. Measuring again: If measuring again, please unclinch the 

‘scan’ button and wait for the ‘   ’ symbol to display, then 

press ‘scan’ button to measure again.  Note: The time 

between each reading should be not less than 12 seconds otherwise there is not any 

change on the LCD.

5. Memory seach: Press the ‘on/recall’ button, the last ten memories (NO.9-NO.0) will take 

turns to display on the LCD as Fig. C and Fig. D.

6. The LCD will displays ‘Er 1’ as Fig. E and cannot displays temperature when the ambient 

temperature is out of the range of 16°C to 35°C.

Fig. A

Fig. B

newborn -

1 year

1 year-adult

Fig. C

Fig. D

Fig. E

Summary of Contents for 25579

Page 1: ...h Instruments Co Ltd Building 2 1 Fuzhu Nan RD Wuchang Town Yuhang District Hangzhou Zhejiang 310023 China Made in China Shanghai International Holding Corp GmbH Europe Eiffestrasse 80 20537 Hamburg Germany 25579 ET 100B PROFESSIONAL MEDICAL PRODUCTS IP22 Importato da Imported by Importé par Importado por Gima S p A Via Marconi 1 20060 Gessate MI Italy gima gimaitaly com export gimaitaly com www g...

Page 2: ...i funzionamento Temperatura 16 C 35 C Umidità 85 RH Pressione atmosferica 700 1060hPa Altitudine 2000m Conservazione e condizioni di trasporto Temperatura 25 C 55 C Umidità 85 RH Visualizzazione temperatura 0 1 C Precisione 0 2 C da 35 5 C a 42 0 C 0 3 C da 34 0 C a 35 5 C da 42 0 C a 44 0 C Display display a cristalli liquidi a 3 5 cifre unità di temperatura Centigradi visualizzazione della memor...

Page 3: ...ualsiasi sistema radio e dai cellulari 12 Mantenere il dispositivo in un luogo asciutto e pulito 13 Il grado di protezione contro le scosse elettriche è parte applicata di tipo BF 14 Lo smaltimento della batteria e del congegno deve essere conforme ai requisiti ambientali locali 15 Questo dispositivo comprende parti di piccole dimensioni non ingoiarle o aspirarle 16 Non applicare una forte scossa ...

Page 4: ...bevuto di alcol 70 isopropile per pulire l involucro del termometro e la sonda di misurazione prima di ogni uso Assicurarsi che nessun liquido penetri all interno del termometro 3 Non pulire il dispositivo con prodotti abrasivi solventi o benzina e non immergerlo in acqua o altri liquidi detergenti Evitare di procurare graffi alla superficie della membrana della sonda o al display Sostituzione del...

Page 5: ... autorizzato nella Comunità europea IP22 Grado di protezione dell involucro Smaltimento RAEE Parte applicata di tipo BF Corrente continua Limite di temperatura Limite di umidità Smaltimento Il prodotto non deve essere smaltito assieme agli altri rifiuti domestici Gli utenti devono provvedere allo smaltimento delle apparecchiature da rottamare portandole al luogo di raccolta indicato per il ricicla...

Page 6: ...tude 2000m Storage and transport condition Temperature from 25 C to 55 C Humidity 85 RH Display resolution temperature range 0 1 C Accuracy 0 2 C from 35 5 C to 42 0 C 0 3 C from 34 0 C to 35 5 C from 42 0 C to 44 0 C Display liquid crystal display 3 5 digits temperature unit centigrade display of memory last ten memories low voltage warning the LCD display Power consumption 0 5 milliwatt in measu...

Page 7: ... step on or vibrate the main unit How to use Measuring human body temperature in the Ear Canal 1 Press the on recall button to turn on the thermometer a beep sound is heard and the LCD displays as Fig A in one second When the LCD displays as Fig B now ready to measure 2 Straighten the ear canal by pulling the outer ear up and back to give a clear view of the eardrum For children under 1 year Pull ...

Page 8: ... accurately under the condition of low voltage 2 The thermometer is supplied with one 3 V LITHIUM BATTERY CR 2032 Insert new battery when the low voltage symbol appears on the LCD 3 Screw off the bolt and remove the battery cover and take out the old battery 4 Place new battery according to the or 5 Please take out the battery to avoid battery leaking if unit not used for over six months 6 The dis...

Page 9: ... est au dessous de 34 0 C Écran H C lorsque la température est supérieure à 44 0 C Cadre de fonctionnement Température 16 C 35 C Humidité 85 RH Pression atmosphérique 700 1060hPa Altitude 2000m Stockage et conditions de transport Température de 25 C à 55 C Humidité 85 RH Affichage température 0 1 C Précision 0 2 C de 35 5 C à 42 0 C 0 3 C de 34 0 C à 35 5 C de 42 0 C à 44 0 C Écran écran à cristau...

Page 10: ...es radio et les téléphones portables 12 Cet appareil doit toujours être conservé dans un endroit propre et sec 13 Le degré de protection contre les chocs électriques est de type BF partie appliquée 14 L élimination de la batterie et du dispositif doit être conforme aux exigences locales en matière d environnement 15 Ce dispositif inclut de petites pièces éviter de les inhaler ou de les avaler 16 N...

Page 11: ...prise entre 25 C et 55 C 2 Utiliser un coton tige imbibé d alcool 70 Isopropie pour nettoyer le boîtier du thermomètre et la sonde de mesure après chaque utilisation S assurer qu aucun liquide ne pénètre dans le thermomètre 3 Ne jamais utiliser d agents de nettoyage abrasifs de diluants ou d essence pour le nettoyage et ne jamais immerger l instrument dans de l eau ou dans d autres liquides de net...

Page 12: ... la B2B standard Gima de 12 mois Attention lisez attentivement les instructions avertissements Suivez les instructions d utilisation Á conserver dans un endroit frais et sec Á conserver à l abri de la lumière du soleil Fabricant Date de fabrication Numéro de lot Code produit Dispositif médical conforme à la directive 93 42 CEE Représentant autorisé dans la Communauté européenne IP22 Degré de prote...

Page 13: ...cionamiento Temperatura 16 C 35 C Humedad 85 RH Presión atmosférica 700 1060hPa Altitud 2000m Almacenamiento y condiciones de transporte Temperatura 25 C a 55 C Humedad 85 RH Visualización temperatura 0 1 C Precisión 0 2 C 35 5 C a 42 0 C 0 3 C de 34 0 C a 35 5 C de 42 0 C a 44 0 C Visualizador visualizador de cristales líquidos de 3 5 cifras unidad de temperatura Celsius visualización de la memor...

Page 14: ...ales locales 15 El dispositivo contiene piezas pequeñas no las inhale ni las ingiera 16 No aplique choques fuertes caiga pise o haga vibrar la unidad principal Empleo Medir la temperatura del cuerpo humano Por favor retire la cinta aislante de la batería antes de usarla por primera vez 1 Pulse el botón on recall para encender el termómetro se emitirá un pitido y el visualizador LCD se pondrá como ...

Page 15: ...líquido penetre en el interior del termómetro 3 No utilice agentes de limpieza abrasivos diluyentes ni gasolina para limpiarlo No sumerja el termómetro en agua u otros líquidos de limpieza Trate de no rayar la superficie del lente de la sonda o la pantalla Sustitución de las baterías 1 Cuando la tensión de la batería es baja el visualizador LCD muestra el símbolo se aconseja colocar una batería nu...

Page 16: ...aplica la garantía B2B estándar de Gima de 12 meses Precaución lea las instrucciones advertencias cuidadosamente Siga las instrucciones de uso Conservar en un lugar fresco y seco Conservar al amparo de la luz solar Fabricante Fecha de fabricación Número de lote Código producto Dispositivo médico segun a la Directiva 93 42 CEE Representante autorizado en la Comunidad Europea IP22 Tasa de protección...

Reviews: