background image

U

s

e t

h

e P

U

s

h B

U

t

tO

n

4

Use the PUsh BUttON

 

|

 PiPetMaN® M CONNeCteD

Use the Push Button

 

Press the push button  

to turn on or wake up  

the startup screen

 

a self-calibration 

test will begin as the 

firmware resets the 

piston 

 

the pipette is preset to 

PiPet

, also known as 

standard pipetting

Adjust the Volume

1.  hold your PiPetMaN M Connected in a 

nearly vertical position.

2.  turn the push button half way.  

the screen will display:  

Click to change volume.”

3.  Press the push button; the volume on the 

display will start blinking, you can now 

adjust the volume:

 

turn the push button either 

clockwise to decrease volume 

or counter clockwise to increase 

volume, as indicated on the button.

 

Press the push button one time when 

finished. the volume is locked.

4.  select a suitable tip for the pipette.

5.  PiPetMaN M Connected is now ready to 

pipette.

Figure 2

Volume range 

displayed on startup 

screen

Figure 3

screen displayed 

during calibration

Firmware 

Version

Number of 

readjustments

Figure 4

Volume screen with 

pipetting mode 

displayed

Summary of Contents for PIPETMAN M CONNECTED

Page 1: ...Quick Guide EN FR Discover the new experience of connected pipetting on www gilson com D couvrez la nouvelle exp rience de pipetage connect sur www gilson com...

Page 2: ...CE Fully charge the pipette for approximately three hours before use Use only one of the approved charging devices Power supply included in box Stand adapter for use with Gilson CARROUSEL Stands sold...

Page 3: ...push button left or right to set the volume Push to pipette Menu Button Access pipette modes and adjust functions NOTE After three minutes of inactivity the pipette display will turn off and enter sle...

Page 4: ...will display Click to change volume 3 Press the push button the volume on the display will start blinking you can now adjust the volume Turn the push button either clockwise to decrease volume or cou...

Page 5: ...spirates and dispenses the volume set REPETITIVE The pipette distributes the same volume repeatedly in an equal number of predefined aliquots MIX Standard pipette mode followed by a mixing phase i e a...

Page 6: ...votre nouveau PIPETMAN M Connected Cette op ration prend environ 3 heures et s effectue l aide de l un des accessoires suivants Alimentation incluse dans la bo te Adaptateur chargeur pour portoir CAR...

Page 7: ...on vers la gauche ou la droite et le pipetage d une simple pression Le bouton menu Permet d acc der aux modes de pipetage et aux fonctions de r ajustement NOTE PIPETMAN M Connected se met en veille ap...

Page 8: ...demi tour l cran affiche Click to Change Volume 3 Cliquez sur le bouton poussoir le volume affich commence clignoter 4 Vous pouvez maintenant modifier le volume en tournant le bouton poussoir dans le...

Page 9: ...petage mode direct la pipette aspire et distribue le volume choisi REPETITIVE Distribution d un m me volume plusieurs reprises MIX Mode classique de pipetage mode direct suivi d une phase de m lange r...

Page 10: ...Readjustment X Meas vol 10 XX XX L Meas vol 50 XX XX L Meas vol 100 XX XX L Quit Quit Click to confirm Quit Quit Quit Standard readjustment Reset settings Volume limit Beeper ON Contrast Service Adjus...

Page 11: ...custom protocols into PIPETMAN M Connected Please visit www gilson com to learn more about Gilson applications Connexion Bluetooth PIPETMAN M Connected peut tre connect au logiciel PIPETMAN M et aux...

Page 12: ...r normal use and service for a period of 24 months from the date of purchase This warranty shall not apply to pipettes that have been subjected to abnormal use and or improper or inadequate maintenanc...

Reviews: