background image

GilSonic AutoSiever

GA-6

OPERATING MANUAL

Rev: 01/2019

PHONE: 800-444-1508                                                 

        P.O. Box 200, Lewis Center, Ohio  43035-0200 

      

 

740-548-7298 

           E-mail: [email protected]     Product Web Page: 

www.globalgilson.com

                    

FAX: 800-255-5314

 740-548-5314

Summary of Contents for GA-6

Page 1: ...ever GA 6 OPERATING MANUAL Rev 01 2019 PHONE 800 444 1508 P O Box 200 Lewis Center Ohio 43035 0200 740 548 7298 E mail customerservice gilsonco com Product Web Page www globalgilson com FAX 800 255 53...

Page 2: ...Test Phase Indicator Lights 6 4 4 Operating Mode Indicator Lights 6 5 0 Preparing the Sieve Stack Assembly 7 6 0 Establishing Test Sequences 8 6 1 Setting Maximum Amplitude 9 6 2 Establishing Phase Ti...

Page 3: ...from No 20 850 m to No 635 20 m or precision electroform nickel mesh 150 m to 5 m Electroformedmeshsizesof150 mandlargerareavailable for 2 m precision when needed Largerwire wovensievesfromNo 3 1 2toN...

Page 4: ...S unplug or disconnect machine from the power source when the unit is not in operation 2 0 SAFETY INSTRUCTIONS 3 0 UNCRATING SETUP Afterinspectingtheshipmentforexternaldamage immediately unpack the Gi...

Page 5: ...advance to the next entry This function is also used to review saved values in an existing program REC AND SAVE 4 0 CONTROL DISPLAY FUNCTIONS Fuse Voltage Selector Block TheRecallandSavefunctionsareus...

Page 6: ...ethatdecreaseswithparticlesize Thegradualdecrease attheendofthetestservestocleanupseparationofnear sized particles on each sieve Max Amplitude ThisLEDisonatanytimetheprogrammedmaximumamplitude setting...

Page 7: ...ede airflow enough to damage sieves B On a balance sensitive to at least 0 01 gram determine and record the tare mass of parts that will contact the sample during testing Diaphragm Top Cone Each Sieve...

Page 8: ...maximum F PlacetheColumnLockovertheDiaphragmandpressdown until the Stack Locking Bars snap onto the top ring of the Fines Collector Holder G Insert the Sieve Stack Assembly into the sieving chamber o...

Page 9: ...n 0 1 minute 6 second increments 1 minute 18 seconds would be displayed as 1 3 Digits entered appear in the right hand space of the display and push other digits to the left When entering newvalues it...

Page 10: ...C through J or select a previously stored program from one of the ten memory locations by pressing REC and the memory location C Press the RUN STOP button to initiate the test The AutoSieverwillexecu...

Page 11: ...ower cord from the rear of the unit B Remove the 7 Phillips head screws on the top of the unit and remove the case top and handle C Noteorientationofthespeakerandremovethetwolugged wires from the term...

Page 12: ...70 181 GAA 71 65 181 GAA 72 63 181 GAA 72A 60 181 GAA 73 55 250 GAA 74 53 250 GAA 74A 50 250 GAA 75 45 250 GAA 76 40 300 GAA 77 38 300 GAA 77A 35 300 GAA 78 32 300 GAA 78A 30 300 GAA 79 25 400 GAA 80...

Page 13: ...nic AutoSiever GA 6 Page 13 Column Lock GAA 85 Diaphragm GAA 3 Top Cone GAA 87 Standard Spacer GAA 88 Fines Collector GAA 4 Fines Collector Holder GAA 89 Complete Sieve Stack Assembly GAA 2 12 0 REPLA...