Operation
MetPak Base Station User Manual
©
Gill Instruments Ltd
Last Change
Page 50
22 April, 2013
aM2!
Wind Direction/Speed
(direction in Degrees,
speed in Metres/Sec )
and a 2 digit Wind only
Status Code.
atttn<CR><LF>
00053<CR><LF>
0D0!
Retrieve a line of the
above data.
a<dir><mag><status><CR><LF
>
0+029+000.01+00<CR><LF>
aM3!
Temperature (degrees
C), Humidity (%),
Dewpoint (Degrees C)
and Full Sensor Status
Codes.
atttn<CR><LF>
00054<CR><LF>
0D0!
Retrieve a line of the
above data.
a<temp><humidity><dewpoint>
< CR><LF
0+021.6+041.0+007.8+00
<CR><LF>
aM4!
Pressure (Hecto
Pascals/millibars).
atttn<CR><LF>
00051<CR><LF>
0D0!
Retrieve a line of the
above data.
a<pressure><CR><LF>
0+1013.0<CR><LF>
aM5!
PRT, Analogue Input 1,
Analogue Input 2 and
Digital Input 1
Atttn<>CR><LF>
00054<CR><LF>
0D0!
Retrieve a line of the
above data.
a<prt><AI1><AI2><dig1><CR><
LF
0+027.65+0.0034-
0135.000<CR><LF>
AM6!
PRT.
atttn<CR><LF>
00051<CR><LF>
0D0!
Retrieve a line of the
above data.
a<prt><CR><LF>
0+027.65<CR><LF>
AM7!
Analogue Input 1 and
Analogue Input 2
Atttn<>CR><LF>
00052<CR><LF>
0D0!
Retrieve a line of the
above data.
a<AI1><AI2><CR><LF
0+3.5380+017947<CR><LF>
AM8!
Digital Input 1.
atttn<CR><LF>
00051<CR><LF>
0D0!
Retrieve a line of the
above data.
a<dig1><CR><LF>
0+0408.000<CR><LF>
aM9!
Power Voltage (Volts)
atttn<CR><LF>
00011<CR><LF>
0D0!
Retrieve a line of the
above data.
a<voltage><CR><LF>
0+12.5<CR><LF>