WindMaster and WindMaster Pro
1561-PS-0001.
Issue 11 February 2017
________________________________________________________________________________________________________________________
10
PRT (Optional)
Resolution
Not Applicable
0.01
C
Measurement Accuracy
Not Applicable
<
0.1
C (-40 to +50
C)
Measurement Accuracy
Not Applicable
<
0.15
C (+50 to +70
C
General
Weight
1.0kg (1590-PK-020 /W
and 1590-PK-130/W).
2.12kg (1590-PK-050)
1.7kg (1561-PK-020 /W)
Size
750mm x 240mm (1590-PK-020/W)
580mm x 323mm (1590-PK-130/W)
952mm x 240mm (1590-PK-050)
750mm x 240mm (1561-PK-020/W)
Environmental
IP65
IP65
Operating temperature
-40
C to +70
C
-40
C to +70
C
Humidity
< 5 % to 100 %
< 5 % to 100 %
Precipitation
Operation up to 300 mm / hour
Operation up to 300 mm / hour
EMC
Emissions BS EN 61000 - 6 - 3
Immunity BS EN 61000 - 6 - 2
Emissions BS EN 61000 - 6 - 3
Immunity BS EN 61000 - 6 - 2
* WindMaster/WindMaster Pro Accuracy specification applies for wind speed up to range maximum, and for wind incidence up to
30
from the horizontal on units with firmware 2329-700 and higher.
.
# Custom calibration
(
to be specified when ordering, or unit can be returned for calibration) - Wind tunnel calibration is in
accordance with ISO 16622 and traceable to national standards.