Important Safety Information

Notes: 1) Save this Important Safety Information section in a 

readily accessible location.

 2) Although DEF is non-flammable, Diesel is 

flammable. Therefore, for DEF cabinets that are 
attached to Diesel dispensers, follow all the notes 
in this section that pertain to flammable fuels.

This section introduces the hazards and safety precautions 
associated with installing, inspecting, maintaining or servicing 
this product. Before performing any task on this product, read 
this safety information and the applicable sections in this manual, 
where additional hazards and safety precautions for your task 
will be found. Fire, explosion, electrical shock or pressure 
release could occur and cause death or serious injury, if these 
safe service procedures are not followed. 

Preliminary Precautions

You are working in a potentially dangerous environment of 
flammable fuels, vapors, and high voltage or pressures. Only 
trained or authorized individuals knowledgeable in the related 
procedures should install, inspect, maintain or service this 
equipment

.

Emergency Total Electrical Shut-Off

The first and most important information you must know is how to 
stop all fuel flow to the pump/dispenser and island. Locate the 
switch or circuit breakers that shut off all power to all fueling 
equipment, dispensing devices, and Submerged Turbine Pumps 
(STPs). 

 

The EMERGENCY STOP, ALL STOP, and PUMP 
STOP buttons at the cashier

s station WILL NOT 

shut off electrical power to the 

pump/dispenser. This means that even if you activate 
these stops, fuel may continue to flow uncontrolled. 

You must use the TOTAL ELECTRICAL 

SHUT-OFF in the case of an emergency and not the 
console

s ALL STOP and PUMP STOP or similar 

keys.

!

WARNING

!

Total Electrical Shut-Off Before Access

Any procedure that requires access to electrical components or 
the electronics of the dispenser requires total electrical shut off of 
that unit. Understand the function and location of this switch or 
circuit breaker before inspecting, installing, maintaining, or 
servicing Gilbarco equipment.

Evacuating, Barricading and Shutting Off

Any procedure that requires access to the pump/dispenser or 
STPs requires the following actions:

• An evacuation of all unauthorized persons and vehicles from 

the work area 

• Use of safety tape, cones or barricades at the affected unit(s)
• A total electrical shut-off of the affected unit(s)

Read the Manual

Read, understand and follow this manual and any other labels or 
related materials supplied with this equipment. If you do not 
understand a procedure, call the Gilbarco Technical Assistance 
Center (TAC) at 1-800-743-7501. It is imperative to your safety 
and the safety of others to understand the procedures before 
beginning work.

Follow the Regulations

Applicable information is available in National Fire Protection 
Association (NFPA) 30A; 

Code for Motor Fuel Dispensing 

Facilities and Repair Garages

, NFPA 70; 

National Electrical 

Code (NEC)

, Occupational Safety and Health Administration 

(OSHA) regulations and federal, state, and local codes. All these 
regulations must be followed. Failure to install, inspect, maintain 
or service this equipment in accordance with these codes, 
regulations and standards may lead to legal citations with 
penalties or affect the safe use and operation of the equipment.

Replacement Parts

Use only genuine Gilbarco replacement parts and retrofit kits on 
your pump/dispenser. Using parts other than genuine Gilbarco 
replacement parts could create a safety hazard and violate local 
regulations.

Safety Symbols and Warning Words

This section provides important information about warning 
symbols and boxes.

Alert Symbol 

This safety alert symbol is used in this manual and on 

warning labels to alert you to a precaution which must be 
followed to prevent potential personal safety hazards. Obey 
safety directives that follow this symbol to avoid possible injury or 
death.

Signal Words

These signal words used in this manual and on warning labels 
tell you the seriousness of particular safety hazards. The 
precautions below must be followed to prevent death, injury or 
damage to the equipment:

DANGER

:

 

Alerts you to a hazard or unsafe practice 

which will result in death or serious injury.

WARNING

: Alerts you to a hazard or unsafe practice that 

could result in death or serious injury. 

CAUTION

 with Alert symbol: Designates a hazard or 

unsafe practice which may result in minor injury.

CAUTION

 without Alert symbol: Designates a hazard or 

unsafe practice which may result in property or 
equipment damage.

Working With Fuels and Electrical Energy

Prevent Explosions and Fires

Fuels and their vapors will explode or burn, if ignited. Spilled or 
leaking fuels cause vapors. Even filling customer tanks will cause 
potentially dangerous vapors in the vicinity of the dispenser or 
island.

DEF is non-flammable. Therefore, explosion and fire safety 
warnings do not apply to DEF fluid lines.

!

!

!

Summary of Contents for Veeder-Root FlexPay IV Encore 700 S

Page 1: ...MDE 5287B April 2017 FlexPay IV Encore 700 S Bank Note Acceptor BNA Upgrade Kit for E CIM...

Page 2: ...This page is intentionally left blank...

Page 3: ...lectronics 7 Main Door 8 BNA Bracket 9 BNA Assembly 10 Main Door 13 Main Door Electronics 14 Completing Installation 15 Related Documents 17 Abbreviations and Acronyms 17 Wiring Diagrams 19 SECTION 1...

Page 4: ...ii MDE 5287B This page is intentionally left blank...

Page 5: ...arco trained and certified Authorized Service Contractors ASCs Required Tools Phillips Screwdriver 8 mm Socket Nut Driver or Socket Set Button Cap Head Tamperproof Socket Screw M07335B103 Hexagonal Ke...

Page 6: ...2 SECTION 1 INTRODUCTION 1 MDE 5287B This page is intentionally left blank...

Page 7: ...cted unit s A total electrical shut off of the affected unit s Read the Manual Read understand and follow this manual and any other labels or related materials supplied with this equipment If you do n...

Page 8: ...of California to cause birth defects or other reproductive harm WARNING In an Emergency Inform Emergency Personnel Compile the following information and inform emergency personnel Location of acciden...

Page 9: ...the recommended spare parts to the installation site Note Retain all parts including cables nuts bolts screws and so on that are removed These are required in case the unit must be reverted to the or...

Page 10: ...3 REMOVING COMPONENTS 3 Lower Hydraulic Panel 1 Remove the lower hydraulic panel Note Place the lower panel safely to the side Figure 1 Removing Lower Hydraulic Panel Main Door Lower Hydraulic Panel 2...

Page 11: ...bling from the main door 2 Remove all the electronics money volume display totalizers Price Per Unit PPUs etc from the main door Note The electronics will be reused on the new main door Place them saf...

Page 12: ...Open both the doors Push the CD top cover to the other side to expose the top hinge 2 Remove the main door prop rod Note Retain the main door prop rod for reinstallation 3 Pull the top hinge pin out a...

Page 13: ...il and the U channel in the electronics cabinet to the left of the printer see Figure 1 2 Mount the BNA bracket using the four Button Cap Head Tamperproof Socket Screws M07335B007 Figure 1 Mounting BN...

Page 14: ...NSTALLATION 4 BNA Assembly To install the BNA assembly 1 Locate and unpack the BNA Assembly M08074A003 2 Open the top access door and remove the money cassette Figure 2 Installing BNA Assembly Top Acc...

Page 15: ...the two holes with the two studs 4 Mount at the rear side of the BNA using two Q12885 06 Nuts 5 Mount at the lower side using a M00417B101 Screw Figure 3 Positioning BNA Assembly M00417B101 Screw Posi...

Page 16: ...tch Main Door Door open Switch Cable Entering Vault Vault Opens from Top for Money Cassette Access Vault Switch Engagement Section Yellow Cash Cassette Release Slide Connection Point for M02160A001 Ca...

Page 17: ...ult Figure 6 Closing Lid to BNA Vault Lid to BNA Vault Main Door To install the main door 1 Mount the main door to the dispenser 2 Insert the main door lower hinge pin into the lower hinge bracket Fig...

Page 18: ...gure 9 Reinstalling Main Door Electronics and Reconnecting Cables Reconnect Cables Main Door Electronics 2 Repeat steps in REMOVING COMPONENTS on page 6 and INSTALLATION on page 9 for the other side o...

Page 19: ...lose and lock the main door 5 Reassemble the lower panels Figure 10 Reassembling Lower Panels Lower Panels Main Door 6 Apply graphics if required Upgrade to the latest available FlexPay IV software ve...

Page 20: ...MDE 5287B 16 SECTION 4 INSTALLATION 4 This page is intentionally left blank...

Page 21: ...uide MDE 5227 M7 Maintenance Tool User Guide PT 1936 Encore Series Pumps and Dispensers Illustrated Parts Manual PT 1937 Encore 300 Encore 500 500 S Encore 550 Encore 700 S Eclipse Recommended Spare P...

Page 22: ...MDE 5287B 18 SECTION 5 REFERENCE INFORMATION 5 This page is intentionally left blank...

Page 23: ...itch on Side of Vault P192 AC Wiring black white green Through side of Vault AC Wiring black white green Part of AC Wiring Harness M04406A001 To side of BNA Figure 2 Main Door Switch Cable Diagram M02...

Page 24: ...rCard are registered trademarks of MasterCard International Inc Phillips is a registered trademark of Phillips Screw Company Visa is a registered trademark of Visa Inc 2017 Gilbarco Inc 7300 West Frie...

Reviews: