High-Level Installation Procedure
High-Level Installation Procedure
To upgrade the CRIND software to the latest available version, proceed as follows:
If the site uses a POS system, isolate the CRIND two-wire from the CRIND device. For
specific software instructions, refer to
MDE-4902 Encore 700 S Start-up and Service Manual
.
Note: Some third-party POS systems may require the two-wire to be isolated at the
Distribution Box (D-Box).
1
Connect the Category 5 (CAT5) cable from the laptop to the Hub Interface PCB (HIP)/HIP 2/
AFP/DCM2.X board.
Note: You can connect your CAT5 cable directly to the FlexPay Control Board.
2
Download the appropriate CRIND Software bundle to the CRIND device.
Notes: 1) You can load sides A and B at the same time by opening two sessions of the FlexPay
Maintenance Tool (Basic or Advanced).
2) For more information, refer to
“Important Software Information”
.
3
In some instances, the CRIND will automatically coldstart after downloading the new
software.
Note: If the latest CRIND software is already installed, then proceed to step
.
a
Reprogram the CRIND ID and CRIND Mode.
b
Enable the required options (for example, TRIND, contactless, and so on).
c
Warmstart the dispenser. Allow the POS to download the CRIND software application if
applicable. After the download is complete, ensure that all graphics on the display are
correct.
4
Proceed to
on
and complete the steps to install, activate, and
configure the HCRS.
5
Re-establish two-wire communication to the POS.
6
Perform test transactions to validate the installation.
Note: CRIND software V03.4.06 and later is designed to warm start after installation. If any
unexpected behavior occurs when performing test transactions, purge the CRIND to
force a cold start. Retest the unit to verify proper operation of the card reader.