MDE-4017G Mat Reader Assembly Kit (C00016-XXX) Installation Manual · April 2017
Page 9
Installing Mat Reader Assembly
2
Locate the jump jacks on the logic board for mat reader (see
).
Figure 2: Jump Jacks for Baud Rate Setting on Logic Board
3
Set the jump jacks as follows (see
A properly grounded Electrostatic Discharge (ESD) wrist strap must be worn while servicing
any electronic devices or components. Failure to use the electrostatic precautions may
damage the electronic components and void the warranty.
CAUTION
Following are the baud rate settings:
Mat Reader Baud Rates
Baud Rate (see Note) BAUD 1
BAUD 2
BAUD 4
4800
OUT
OUT
OUT
2400
IN
OUT
OUT
1200
OUT
IN
OUT
300
IN
IN
OUT
38400
OUT
OUT
IN
19200
IN
OUT
IN
9600
OUT
IN
IN
4800
IN
IN
IN
Note: 4800 is the default Mat Reader value.
4
If you are
NOT
daisy chaining the mat reader interface boxes, reinstall the cover removed in
step
.
Note: Daisy chaining is connecting the output from one interface box to the input of the
another interface box, the address of the second mat reader must match the address on
the first mat reader.
5
If you
ARE
daisy chaining the mat reader interface boxes, go to
to set addresses on the logic board.