MDE-4017G Mat Reader Assembly Kit (C00016-XXX) Installation Manual · April 2017
Page 13
Installing Mat Reader Assembly
3
Double-loop the JDC1 end of the power supply cable through the Magnetically Coupled
Transient Suppressor (Q11433-107) with the bead in the open position, then snap the bead shut
(see
).
Figure 8: Wall-mount Power Supply Cable with Ferrite
Magnetically Coupled Transient
Suppressor (Q11433-107)
Power Supply Cable, Double-looped
Power Supply Cable
Completing Installation
To complete the installation, connect the cables as follows:
1
Route all cables near the interface box end through the magnetically coupled transient
suppressor and snap the ferrite bead closed (see
Figure 9: Low Frequency Mini Mat Reader Connections
Power Supply
Cable
Work Area Cables
Interface Box to
Mat Reader Cable
Magnetically Coupled
Transient Suppressor
(Q11433-107)
Interface Box
Figure 10: Ferrite on Interface Cables
Ferrite on Interface Cables