Capricorn S2X MEC Installation Note 

 

DCP0000247(C)

 

 

 

Connecting the Power Cables 

The Capricorn CPE is powered with a 48VDC external power source. The CPE power connection uses the two 
supplied Gilat power cables (CB000912) that include a 7A fuse on the “+” wire.  
An accessible two pole circuit breaker (Rated 10A) must be provided in the building for the DC power feed source. 

 

 

C

AUTION

 

T

O  PREVENT  DAMAGE  TO  THE 

VSAT,

  AVOID  DISCONNECTING  THE  POWER  SOURCE  WHILE  THE  CPE  IS 

OPERATIONAL

 
Connecting the RF Cables 

Connect the two RF cables (from the LNB and ODU) to the RF-IN and RF-OUT connectors, respectively, as shown 
below, using a recommended torque of 13 lb*ft/in (1.5 N/m). 
 

 

C

AUTION

 

I

N  ORDER  TO  PREVENT  DAMAGE  TO  THE  RF  CONNECTORS

,

  SECURE  THE  CABLES  TO  A  PERMANENT

,

  STATIC 

OBJECT  SUCH  AS  A  TABLE  OR  PIPE

,

  AT  A  DISTANCE  OF 

25-60

  CM 

(10-25

  IN

.)

 

F

ROM  THE  CPE

,

  PRIOR  TO 

CONNECTION. 

 

 

 

Figure 1: Capricorn S2X MEC CPE Cables 

 

Figure 2: Capricorn S2X MEC Rack-Mount 

(Optional) Attaching Rack Mount Back Ears 

To install the CPE with the rear panel facing forward: 

1.

 

Remove the screws holding the rack-mount 
ears. 

2.

 

Remove the rack-mount ears. 

3.

 

Secure the screws to the front panel. 

4.

 

Remove the screws from the rear panel. 

5.

 

Install the rack-mount ears to the rear panel 
and tighten the screws.

 

 