background image

Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.

Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.

When the Unit is in Use

   Should  the  following  irregularity  be  found  during 
   use, immediately switch  off  the  power, disconnect
   the  power  supply   plug  from  the  AC  outlet  and 
   contact  your  nearest   dealer.  Make  no  further
   attempt  to operate the unit in this  condition as  this
   may cause fire or electric  shock.
     If  you  detect  smoke  or  a strange  smell coming
     from the unit.
     If water or any metallic object gets into the unit
     If the unit falls, or the unit case breaks
     If the power supply cord is damaged (exposure  of
     the core, disconnection, etc.)
     If it is malfunctioning (no tone sounds.)

   To prevent  a fire or electric  shock, never open  nor
   remove  the  unit  case  as  there  are  high  voltage 
   components  inside  the  unit.  Refer all servicing to
   your  nearest  dealer.

  

 Do  not  place  cups,  bowls,  or other containers  of
 liquid  or  metallic  objects on top of the unit. If  they 
 accidentally spill  into the unit, this may cause a fire 
 or electric shock.

  Do   not   insert    nor   drop    metallic    objects   or 
  flammable  materials  in  the  ventilation slots  of the
  unit's  cover,  as  this  may  result  in  fire  or electric
   shock.

 Be sure to read the instructions in this section carefully before use.
 Make sure  to observe  the instructions in this manual as the conventions of safety symbols and messages
 regarded as very important precautions are included.
 We also recommend you keep this instruction manual handy for future reference.

Safety Symbol and Message Conventions

Safety  symbols and messages  described  below are used in this manual to prevent  bodily injury and  property 
damage  which  could  result  from  mishandling.  Before  operating  your  product,  read  this  manual  first  and
 understand the safety symbols and messages so you are thoroughly aware of the potential safety 

When Installing the Unit

   Do not  expose  the unit  to rain or an  environment
   where it may be splashed by water or other liquids, 
   as doing so may result in fire or electric shock.

   Use the unit only with the voltage  specified  on the
   unit.  Using  a  voltage  higher  than  that  which  is
   specified may result in fire or electric shock.

   Do not cut, kink, otherwise damage  nor modify the
   power  supply  cord.  In  addition,  avoid  using  the
   power cord in close proximity to heaters, and never
   place heavy objects -- including the unit  itself -- on 
   the  power  cord,  as doing so may result  in  fire or 
   electric shock.

 Be sure  to replace  the unit's  terminal  cover  after
 connection  completion.  Because  high  voltage  is
 applied to the speaker terminals, never touch these 
 terminals to avoid electric shock.

 Be  sure  to  ground  to  the  safety   ground  (earth)
 terminal to avoid electric shock. Never  ground to a 
 gas pipe as a catastrophic disaster may result.

 Avoid  installing  or  mounting  the  unit  in  unstable
 locations, such  as  on a rickety  table  or  a slanted
 surface.  Doing  so  may  result  in  the  unit   falling
 down,   causing   personal   injury  and/or  property 
 damage.

1. SAFETY PRECAUTIONS

3

WWW.GIGAMEDIA.NET

Summary of Contents for GGM IPABC15POE

Page 1: ...e optimum results from this unit We also recommend that you keep this manual handy for future reference IP NETWORK PA SYSTEM POE LAN BATT SUPPLY 24V 2A STATE IP 192 168 169 169 OWNER S MANUAL GGM IPABC8POE GGM IPABC15POE NETWORK AUDIO ADAPTER WWW GIGAMEDIA NET ...

Page 2: ...SAFETY PRECAUTIONS PRODUCT APPLICATION 5 3 FUNCTION FEATURES 5 4 NAME AND UNCTION 5 TERMINAL CONFIGURATION OPERATING INSTRUCTIONS CONNECTION DIAGRAM BLOCK DIAGRAM TECHNICAL PARAMETERS 6 7 6 10 7 10 8 2 WWW GIGAMEDIA NET ...

Page 3: ...ions of safety symbols and messages regarded as very important precautions are included We also recommend you keep this instruction manual handy for future reference Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling Before operating your product read this manual ...

Page 4: ...upply plug or in the wall AC outlet a fire may result Clean it periodically In addition insert the plug in the wall outlet securely Switch off the power and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more Doing otherwise may cause a fire or electric shock When Installing the Unit Never plug in nor remove the power sup...

Page 5: ...he construction is simple and convenient and the maximum connection distance is up to 80 meters 4 Digital power amplifier with intelligent gain adjustment adaptive power supply and automatic power adjustment was equipped And it is always in the working state of performance optimization and efficiency maximization 5 Built in full band and high sensitivity speaker unit also with abundant power and h...

Page 6: ... green light off 2 Powering on light green on red light off 3 The normal idle alternating red and green alternately 1 0 seconds interval bright red and green two color 4 The normal broadcast bright green on red off 5 The network failure red flash and green off 0 2 seconds interval then bright red on The factory terminal IP address is 192 168 168 166 Subnet mask 255 255 0 0 Gateway 0 0 0 0 Service ...

Page 7: ...for future maintenance After the system planning is completed please configure parameters of each terminal includes terminal IP address subnet mask gateway and server address 1 Installing software Find the IP network broadcast system software installation package double click to open it click on the program terminal configuration tool after the installation of the program is completed as shown bel...

Page 8: ...he computer should be set in the same network segment as the terminal because the default IP of terminal is 192 168 168 166 so the computer s local IP address should also be set to 192 168 168 X otherwise it maybe not match the IP terminal address Step 3 In the window of Terminal Configuration Tool fill in correct IP address Subnet mask Gateway IP and Server IP as below Step 4 left click on the wr...

Page 9: ... in the queried terminals list then cancel the choice of broadcast on the left interface modify the IP address and click for configuration Notes If the terminal data can t be queried or the network is blocked the pop up window will say Reconfigure the IP address or IP adress writing error In this case please reconfigure the network check the network cable and turn off the firewall etc WWW GIGAMEDI...

Page 10: ...supply Motherboard RJ45 Network board PA3123D2 12V power supply Speakers 6 CONNECTION DIAGRAM 7 BLOCK DIAGRAM POE Switch POE LAN BATT SUPPLY 24V 2A STATE Server Speaker 01 Speaker 02 Speaker N POE LAN BATT SUPPLY 24V 2A STATE POE LAN BATT SUPPLY 24V 2A STATE WWW GIGAMEDIA NET ...

Page 11: ...3 8K 48K 8K 512Kbps Audio Format Sampling Rate Bit rate 20 80 Relative humidity no condensing 5 40 Working Tempreture Working Humidity POE IEEE 802 3af DC 24V 2A 12W 24W Power Specifications Power Consumption 12W 12W 0 8Kg 1 2Kg N W 180X98 212X147 Dimension mm 160mm Installation dimensions 184mm Overvoltage overcurrent circuit Power protection circuit Woofer Coaxial speakers 8Ω 6W Loaded speakers ...

Page 12: ...VersionV0 1 IP NETWORK PA SYSTEM ...