- 61 -
BIOS Setup
5-2-8
Chipset Configuration
(Note) When the power policy is controlled by BMC, please wait for 15-20 seconds for BMC to save the
last power state.
Parameter
Description
Restore AC Power Loss
(Note)
Defines the power state to resume to after a system shutdown that is
due to an interruption in AC power. When set to Last State, the system
will return to the active power state prior to shutdown. When set to
Power Off, the system remains off after power shutdown.
Options available: Last State/Power Off/Power On. The default setting
depends on the BMC setting.
Skip Above 4G Decoding for VGA
Enable/Disable 64bit capable devices to be decoded in Skip Above 4G
Address VGA Space.
Options available: Enabled/Disabled. Default setting is
Disabled
.
P2P Bridge IO Size
Sets P2P Bridge IO aligned to the size.
Options available: 0x100/0x150/0x1000. Default setting is
0x1000
.
Chassis Opened Warning
Enable/Disable the chassis intrusion alter function.
Options available: Enabled/Disabled/Clear. Default setting is
Disabled
.
Summary of Contents for S451-3R1
Page 1: ...S451 3R1 Intel 4U 42 Bay Dual Processors Storage Server User Manual Rev 1 0...
Page 15: ...15 Hardware Installation 1 3 System Block Diagram...
Page 16: ...This page intentionally left blank...
Page 24: ...This page intentionally left blank...
Page 33: ...33 System Hardware Installation Pull Pull 4 5 Push Push 6...
Page 34: ...System Hardware Installation 34 2 5 Hard Drive 1 2 3 5 4 6...
Page 36: ...System Hardware Installation 36 2 2...
Page 44: ...44 Motherboard Components This page intentionally left blank...
Page 64: ...BIOS Setup 64 5 2 11 Intel R I210 Gigabit Network Connection...
Page 66: ...BIOS Setup 66 5 2 12 VLAN Configuration...