- 57 -
BIOS Setup
Parameter
Description
Serial Port for Out-of-Band
Management / Windows
Emergency Management
Services (EMS) Console
Redirection
(Note)
EMS console redirection allows the user to configure Console Redirection
Settings to support Out-of-Band Serial Port management.
Options available: Enabled, Disabled. Default setting is
Disabled
.
Serial Port for Out-of-Band
EMS Console Redirection
Settings
Press [Enter] to configure advanced items.
Please note that this item is configurable when Serial Port for Out-of-
Band Management EMS Console Redirection is set to Enabled.
Out-of-Band Mgmt Port
– Microsoft Windows Emergency Management Service (EMS) allows
for remote management of a Windows Server OS through a serial
port.
– Default setting is
COM1
.
Terminal Type EMS
– Selects a terminal type to be used for console redirection.
– Options available: VT100, VT100PLUS, VT-UTF8, ANSI. Default
setting is
VT100PLUS
.
Bits per second EMS
– Selects the transfer rate for console redirection.
– Options available: 9600, 19200, 57600, 115200. Default setting is
115200
.
Flow Control EMS
–
Flow control can prevent data loss from buffer overflow. When
sending data, if the receiving buffers are full, a 'stop' signal can
be sent to stop the data flow. Once the buffers are empty, a 'start'
signal can be sent to re-start the flow. Hardware flow control uses
two wires to send start/stop signals.
– Options available: None, Hardware RTS/CTS, Software Xon/Xoff.
Default setting is
None
.
Summary of Contents for R183-S94-AAC1
Page 13: ...Hardware Installation 13 1 3 System Block Diagram 1 3 1 R183 S94 AAC1 1 3 2 R183 S94 AAC2 ...
Page 38: ...System Hardware Installation 38 CPU1 CPU0 A B C D E D D A C E B E F F F G G G H H H ...
Page 59: ... 59 BIOS Setup 5 2 4 PCI Subsystem Settings ...
Page 68: ... 68 BIOS Setup 5 2 12 Intel R Ethernet Controller X710 for 10GBASE T ...
Page 73: ... 73 BIOS Setup 5 3 1 Processor Configuration ...