t 1: TURN-ON DELAY TIME
t 2: RISE TIME
t 3: POWER GOOD DELAY
t 4: POWER FAIL DELAY
t 5: HOLD-UP TIME
2-10 PROTECTION
When OCP, OVP, OTP, or short protection is triggered, the
main output will be latched off. The main outputs can be reset
by cycling the DC remote on/off or AC power +5Vsb output is
automatically recovered when a fault condition is removed.
2-10-1.OVER CURRENT PROTECTION
No exceeding 240VA every output voltage (Beside
of 12V)
+12V1, +12V2 output 25A max (GE-S800A-D1;
GE-M800A-D1; GE-S680A-D1; GE-M680A-D1)
+12V3, +12V4 output 38A max (GE-S800A-D1;
GE-M800A-D1; GE-S680A-D1; GE-M680A-D1)
2-10-2.OVER VOLTAGE PROTECTION
+3.3V output 4.5V max.
+5.0V output 7.0V max.
+12.0V output 15.6V max.
2-10-3.UNDER VOLTAGE PROTECTION
12V1 & 12V2 output 9.5V min
12V3 & 12V4 output 9.5V min
+5V output 4.1V min
+3.3V output 2.55V min
2-10-4.SHORT PROTECTION
All output to GND
2-10-5.OVER TEMPERATURE PROTECTION
The power supply includes an over- temperature
sensor, which can trip and shutdown the power
supply at 100°C. Such an overheated condition is
typically the result of internal current overloading or
a cooling fan failure.
2-11 ENVIRONMENT
2-11-1 Operating Temp
En
glis
h
13