- 85 -
BIOS Setup
Parameter
Description
Memory Addressing
Press [Enter] for more options.
NUMA notes per socket
–
Specifies the number of desired NUMA (Non-uniform Memory
Access) notes per socket. Zero will attempt to interleave the two
sockets together.
– Options available: NPS0/NPS1/NPS2/NPS4/Auto. Default option
is
Auto
.
Memory interleaving
– Allows for disabling memory interleaving. Note that NUMA nodes
per socket will be honored regardless of this setting.
– Options available: Disabled/Auto. Default option is
Auto
.
Memory interleaving size
– Controls the memory interleaving size. The valid value are AUTO,
256 bytes, 512 bytes, 1Kbytes or 2Kbytes. This determines the
starting address of the interleave (bit 8, 9, 10 or 11).
– Options available: 256 Bytes/512 Bytes/1 KB/2KB/Auto. Default
setting is
Auto
.
1TB remap
– Attempt to remap DRAM out of the space just below the 1TB
boundary. The ability to remap depends on DRAM configuration,
NPS, and interleaving selection, and may not always be possible.
– Options available: Do not remap/Attempt to remap.Auto. Default
option is
Auto
.
DRAM map inversion
– Inverting the map will cause the highest memory channels to get
assigned the lowest addresses in the system.
– Options available: Disabled/Enabled/Auto. Default option is
Auto
.
ACPI
Press [Enter] for more options.
ACPI SRAT L3 Cache as NUMA Domain
– Enabled: Each CCX in the system will be declared as a separate
NUMA domain.
– Disabled: Memory Addressing \ NUMA nodes per socket will be
declared.
– Options available: Disable/Enable/Auto. Default option is
Auto
.
ACPI SLIT Distance Control
– Determines how the SLIT distances are declared.
– Options available: Manual/Auto. Default option is
Auto
.
ACPI SLIT remote relative distance
– Set the remote socket distance for 2P systems as near (2.8) or far
(3.2).
– Options available: Near/Far/Auto. Default option is
Auto
.
Summary of Contents for G492-Z51
Page 1: ...G492 Z51 HPC Server 4U DP 10 x Gen4 GPU Server User Manual Rev 1 0 ...
Page 10: ... 10 This page left intentionally blank ...
Page 16: ...Hardware Installation 16 This page intentionally left blank ...
Page 28: ...System Hardware Installation 28 3 5 4 6 6 6 ...
Page 30: ...System Hardware Installation 30 3 5 4 ...
Page 42: ...System Hardware Installation 42 4 ...
Page 46: ...System Hardware Installation 46 This page left intentionally blank ...
Page 65: ... 65 BIOS Setup 5 2 8 PCI Subsystem Settings ...
Page 70: ...BIOS Setup 70 5 2 11 SATA Configuration ...
Page 75: ... 75 BIOS Setup 5 2 16 Intel R Ethernet Controller X550 ...