- 41 -
System Hardware Installation
3-12 Removing and Installing the PCIe RAID Card
Follow these instructions to replace the PCIe RAID card:
1. Disconnect any cables that connect to the PCIe RAID card.
2. Loosen the thumbnail screw securing the PCIe RAID card lock in place.
3. Extend the PCIe RAID card lock.
4. Gently pull the PCIe RAID card in the direction indicated to disconnect the PCIe RAID.
5. Reverse the previous steps to install the replacement PCIe RAID card.
2
3
1
•
This section applies to G482-Z51 only.
•
Voltages can be present within the server whenever an AC power source is connected. This
voltage is present even when the main power switch is in the off position. Ensure that the system
is powered off and all power sources have been disconnected from the server prior to installing a
PCIe card.
•
Failure to observe these warnings could result in personal injury or damage to equipment.
Summary of Contents for G492-Z51
Page 1: ...G492 Z51 HPC Server 4U DP 10 x Gen4 GPU Server User Manual Rev 1 0 ...
Page 10: ... 10 This page left intentionally blank ...
Page 16: ...Hardware Installation 16 This page intentionally left blank ...
Page 28: ...System Hardware Installation 28 3 5 4 6 6 6 ...
Page 30: ...System Hardware Installation 30 3 5 4 ...
Page 42: ...System Hardware Installation 42 4 ...
Page 46: ...System Hardware Installation 46 This page left intentionally blank ...
Page 65: ... 65 BIOS Setup 5 2 8 PCI Subsystem Settings ...
Page 70: ...BIOS Setup 70 5 2 11 SATA Configuration ...
Page 75: ... 75 BIOS Setup 5 2 16 Intel R Ethernet Controller X550 ...