- 35 -
System Hardware Installation
5. Identify the corresponding heatsink and then place the heatsink onto the GPU card ensuring that
the captive screws of the heatsink align with the screw holes on the GPU card.
NOTE:
The system features two types of heatsink. Refer to the end of this section for
detailed
information.
6. Fasten the four captive screws in sequence (1
g
2
g
3
g
4) to secure the heatsink in place.
NOTE:
When installing the heatsink, technicians must use a torque screwdriver and follow the
screw tightening torque for appropriate tightening of screws.
The screw tightening torque: 0.4+/- 0.05 N-m (3.5+/-0.5 in-lbf)
NOTE:
The system features two types of heatsink. Refer to the end of this section for
detailed
information.