background image

 

 

 

 

 

4. 

G.hn Cable and Connectors  

 

 

Device 

 

Supported connectors 

 

Supported MIMO 

 

Phone Line MDU 

 

RJ45 8P8C 

RJ11 6P6C

 

 

RJ11 6P4C 
RJ11 4P4C 

 

 

RJ11 4P2C 

 

 

Phone Line CPE 

 

RJ11 6P6C 
RJ11 6P4C  
RJ11 4P4C 

 

RJ11 4P2C 

 

 

 

2 Pairs Cable Application  

MDU needs to be configured as MIMO mode. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for G4224Tv2

Page 1: ...G4224Tv2 Twisted Pair Switch Quick Start Guide GIGA Copper Networks GmbH ...

Page 2: ...rounding wire 2 Hardware Introduction 2 1 Physical Dimensions Dimension W D H 440mm 268mm 44 5mm 19 inch rack mount 1U height Case Aluminum degree of protection IP30 Weight 5 2Kg Operating temperature 0 50 Storage temperature 25 80 Humidity 5 95 RH Non condensing Consumption No load 55W Full load 85W ...

Page 3: ...can be used for accessing the device CLI command line interface for out of band management USB USB type C connector for connection to a computer control administration The driver needs to be installed correctly SYNC IN OUT 2 BNC connectors used for transmitting 50Hz SYNC clock POTS 24 24 PSTN Pass through ports RJ21 connector ON OFF Power Switch Turn on or turn off the power supply INPUT 100 240 V...

Page 4: ...s no connection to this port Yellow On The G hn port connection is normal and PHY rate is low Off There is no connection to this port or the PHY rate is high and Green LED is On PWR Power status Yellow On The power is on and supplying the current to the system Off The power is off or it is not supplying the current to the system SYS System status Green On System is started Off System does not star...

Page 5: ...tion 3 2 Sync Installation NOTE If there is only one G4224T you needn t use SYNC port But if there is more than one G4224T just only one is the primary and the rest are secondary SYNC signal is sent out from the master Please power the primary and then the secondary ...

Page 6: ...n it Step 4 Connect power cable console cable and UTP cable then power on the chassis Step 5 Connect client devices CPE to the G hn port of G4224T if CPEs is connected the corresponding G hn LED will light up as below NOTE If there are more than one G4224T chassis need to be installed please left 0 5U space between chassis to achieve better cooling effect ...

Page 7: ...vice Supported connectors Supported MIMO Phone Line MDU RJ45 8P8C RJ11 6P6C RJ11 6P4C RJ11 4P4C Y RJ11 4P2C N Phone Line CPE RJ11 6P6C RJ11 6P4C RJ11 4P4C Y RJ11 4P2C N 2 Pairs Cable Application MDU needs to be configured as MIMO mode ...

Page 8: ...ed as SISO mode 5 Login 5 1 Default Configuration Default IP Address IP Address 192 168 0 252 IP Sub network 255 255 255 0 Accounts User name superuser Password 123 5 2 Login via WEB Interface You can browse http 192 168 0 252 and type user name and password ...

Page 9: ...rown 4 White 4 30 Gray 5 White 5 31 Blue 6 Red 6 32 Orange 7 Red 7 33 Green 8 Red 8 34 Brown 9 Red 9 35 Gray 10 Red 10 36 Blue 11 Black 11 37 Orange 12 Black 12 38 Green 13 Black 13 39 Brown 14 Black 14 40 Gray 15 Black 15 41 Blue 16 Yellow 16 42 Orange 17 Yellow 17 43 Green 18 Yellow 18 44 Brown 19 Yellow 19 45 Gray 20 Yellow 20 46 Blue 21 Purple 21 47 Orange 22 Purple 22 48 Green 23 Purple 23 49...