041-03 - Gas fryers
6
Model
CFG15
CFG15D
KFG15
KFG15D
KFG20
KFG20D
OPFG15
OPFG15D
OPFG20
OPFG20D
Description
Gas deep fat fryer - 1 tank
Gas deep fat fryer - 2 tanks
Gas deep fat fryer - 1 tank - oil container whit filter
Gas deep fat fryer - 2 tanks - 2 oil containers whit filter
Gas deep fat fryer - 1 tank - oil container whit filter
Gas deep fat fryer - 2 tanks - 2 oil containers whit filter
Gas deep fat fryer - 1 tank
Gas deep fat fryer - 2 tanks
Gas deep fat fryer - 1 tank
Gas deep fat fryer - 2 tanks
Dimensions
(LxPxH+H1) - mm.
400 x 700 x 875 (1085)
800 x 700 x 875 (1085)
400 x 900 x 875 (1090)
800 x 900 x 875 (1090)
400 x 900 x 875 (1090)
800 x 900 x 875 (1090)
400 x 900 x 530
800 x 900 x 530
400 x 900 x 530
800 x 900 x 530
Basins Nr.
1
2
1
2
1
2
1
2
1
2
Capacity (Lt.)
15
15+15
15
15+15
20
20+20
15
15+15
20
20+20
Gas connector
1/2" ISO R228
1/2" ISO R228
3/4" ISO R228
3/4" ISO R228
3/4" ISO R228
3/4" ISO R228
3/4" ISO R228
3/4" ISO R228
3/4" ISO R228
3/4" ISO R228
N.
51BQ2905
51BQ2905
51BQ2905
51BQ2905
51BQ2905
51BQ2905
51BQ2905
51BQ2905
51BQ2905
51BQ2905
2 - CHARACTERISTICS OF THE APPLIANCES
The instructions contained in this manual apply to our Gas deep fat
fryer in the II2H3+ category (see table on page 7).
The data plate is located on the front of the appliance and on the
control panel. It contains all necessary reference data such as the
name of the manufacturer, input pressure, gas type setting, etc.
0051
TIPO/TYPE
CAT/KAT
GAS/GAZ
G30
G31
G20
G25
II2H3B/P
P mbar
30
30
20
-
II2H3+
P mbar
30
37
20
-
-
II2H3+
P mbar
28
37
20
-
25
II2L3B/P
P mbar
30
30
II2ELL3B/P
P mbar
50
50
20
20
II2E+3+
P mbar
28
37
20
25
II2H3B/P
P mbar
50
50
20
-
I2E
P mbar
-
-
20
-
-
-
II2H3B/P
P mbar
30
30
II2H3+
P mbar
28
37
20
-
-
-
-
-
I3B/P
P mbar
30
30
I3+
P mbar
28
37
SE
FI
DK
CZ
SK
SI
IT
CH
PT
ES
IE
GB
GR
NL
DE
FR
BE
AT
CH
LU
EE
LV
LT
EE
LV
LT
NO
MT
CY
IS
HU
CY
MOD.
MOD.
ART.
N.
N.
Qn kW
m
3
/h
MADE IN ITALY
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: - Geschuckt voor:
V AC
kW
Hz
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
G30/G31
28/37 mbar
G20
20 mbar
3 - TECHNICAL DATA