background image

7

8

6

5

4

3

2

1

9

10

11

CONNECTION DIAGRAM:

OVERALL DIMENSIONS:

NOMENCLATURE FOR FRONT FACIA:

Example 1: IMPULSE ON ENERGIZING 

Select the Menu as given below to configure

 the Timers for IMPULSE ON ENERGIZING (Default).

VLL010-05

For Operating procedures of all 35 Defaults modes & Customized modes refer 'User 
Manual' which can be downloaded from our website

 www.gicindia.com.

Example 2: SIGNAL ON/OFF DELAY TYPE  

(Refer Mode No. 13 on pageno. 02) 

Select the Menu as given below to configure the Timers for SIGNAL ON/OFF TYPE 2 
(Customized). 

2.    35 Default Modes.

 

Break: If Break condition is selected in tdt1: ATT action is started, 
there are four ATT actions Reload, Relay Off, New time and No.
Action will be taken after signal changes its state.If break is applied 
no ATT is selected then toggle relay status and stop the cycle.

User can configure the device (Timer 1 or Both Timers) in either Default Mode or 

Customized Mode. Following are the examples of Operating Procedures to configure the 

device in Default or Customized mode. 

T i m

e r 1   m

o d e   s e l e c t i o n

CnFb
both

tmr1
dEFt

dEFt
16

ON time Scale
& time selection

tmr2
dEFt

dEFt
16

ON time Scale
& time selection

coUn
UP

SLoC
YES

PrFL
P1

Device configuration selection (

tMr1

 /

both

)-

Select ‘BOTH’ (Both Timers configuration).

T i m

e r 1   m

o d e   s e l e c t i o n

Timer 1 mode selection 
select Default.

Default mode number selection
Select 16.

Select the time scale & time for 
which relay should remain ON.

Timer 2 mode selection
Select Default.

Default mode number selection
Select 16.

Select the time scale & time for 
which relay should remain ON.

Time counting mode up/down
Select UP counting.

Enable or disable Semi-lock functionality
Select Yes.

At which profile number you want to save this profile
Select P1.

ENTER

ESC

totL

Total time selection for Forward-Reverse Default Mode : 33.
Configure the time for which "Pause-Forward-Pause-Reverse" 
cycle is required to be executed.

FWd

rEv

Forward time (T1 On) Relay 1 selection.

Reverse time (T2 On) Relay 2 selection.

SLoC

Enable or disable Semi-lock functionality. If semilock functionality
is enabled then allow user to edit timings in RUN mode even if
the display is locked, by just pressing enter key for less than 
three seconds. 

PSon

PSoF

Pause-ON-Pause-OFF cyclic mode selection.

Pause-OFF-Pause-ON cyclic mode selection.

OFF time Scale
& time selection

ESC

CnFb
tMr1

tmr1
CUSt

CUSt
SIG

tdt1
YES

tdt1
SA

coUn
doWn

SLoC
YES

PrFL
P1

Device configuration selection (

tMr1

 /

both

)- Select ‘Timer 1'

T i m

e r 1   m

o d e   s e l e c t i o n

Timer 1 mode selection (

dEFt

/

CUSt

)- select Customized

Customized mode selection(

SIG

/

nSIG

)- Select Signal based 

ENTER

IrLS
oFF

Initial output state before required signal state detection. E.g. this
Mode/timer operation start at signal present, then here

 IrLS

 means 

the Output state before signal presents.

Action to be taken on which signal transition (

SP

/

SA

)

Select Signal Present- Select SP- Level.

SIG
SP

rSP
OFF

Relay status after the transition of signal present (

On

/

OFF

)

Select Relay OFF.

Select the time scale & time for which relay should remain OFF

Do you want to take action if the transition of signal occurs during
Run time (

YES

/

No

) - Select Yes.

Select transition on which you want to take any action (

SA

/

SP

)-

Select Signal Absent.

tdt1
brEA

What Action do you want to take if the transition of signal absent
occurs during timing (

brEA

/

rLod

/

rEt

/

rLoF

/

PAUS

)- Select Break

Att
rlod

Select the action after above time completion on signal absent
(

no

/

rLoad

/

rLof

/

nEWt

)- Select Reload

tdt2
YES

Do you want to take action if the transition of signal occurs during
Run time after change in relay state (

YES

/

no

)- Select Yes

tdt2
SA

tdt2
PAUS

Action to be taken on which signal transition (

SA

/

SP

)-

Select SA - Signal Absent

Do you want to take action if the transition of the signal absent
occurs after change in relay state (

PAUS

/

rLoD

/

rEt

/

rloF

)- 

Select Pause

rPtS
YES

Do you want to repeat this cycle after every signal transition 
(YES/no) Select Yes.

Counting method (UP/doWn)- here selected ‘Down’ as an example.

Enable or disable semi-lock functionality
Select Yes.

At which profile number you want to save this profile
Select P1

Example 3:

 ASYMMETRIC CYCLE PULSE START 

(Refer Mode No: 11 on page no 02

Select the menu as given below to configure the timers for ASYMMETRIC CYCLE 
PULSE START (Customized) '

ESC

OFF time Scale
& time selection

CnFb
tMr1

tmr1
CUSt

CUSt
SIG

tdt1
YES

tdt1
SA

coUn
doWn

SLoC
YES

PrFL
P2

Device configuration selection (

tMr1

 /

both

)- Select ‘Timer 1'

Timer1 mode selection

Timer 1 mode selection (

dEFt

/

CUSt

)- select Customized

Customized mode selection(

SIG

/

nSIG

)- Select Signal based 

ENTER

IrLS
oFF

Initial output state before required signal state detection. E.g. this
Mode/timer operation start at signal present, then here

 IrLS

 

means the Output state before signal presents.

Action to be taken on which signal transition (

SP

/

SA

)

Select Signal Present- Select SP- Level.

SIG
SP

rSP
onof

Relay status after the transition of signal present (

On

/

OFF

)

Select Relay ON-OFF.

Select the time scale & time for which relay should remain in the 
OFF state.

Do you want to take action if the transition of signal occurs during
Run time (

YES

/

No

) - Select Yes.

Select transition on which you want to take any action (

SA

/

SP

)-

Select Signal Absent.

dUrn
both

During which relay status you want to take action if the transition
of signal absent during run timing (

on

/

oFF

/

both

)- Select Both.

tdt1
rLof

What action do you want to take if the transition of signal absent
occurs during timing (

brEA

/

rLod

/

rEt

/

rLoF

/

PAUS

) - Select Relay OFF.

rPtS
YES

Do you want to repeat this cycle after every signal transition 
(YES/no) Select Yes.

Counting method (UP/doWn)- here selected ‘Down’ as an example.

Enable or disable semi-lock functionality
Select Yes.

At which profile number you want to save this profile
Select P2

CYCn
onE

CYCr
YES

Number of ON-OFF cycles (

onE

/

tWo

)- Select One.

Do you want to repeat the cycle (

YES

/

no

)- Select :Yes.

ON time Scale
& time selection

Select the time scale & time for which relay should remain in the
 ON state.

tmr2

Default Mode Configuration/Selection - User can select different
default Modes for Timer 1 and Timer 2. There are 35 inbuilt 
default modes available.

Initial relay status before signal detection.

Configure the time for which Relay is required to be ON/OFF.

Number of ON/OFF Cycles i.e. user can select the two cycles with
different ON time & OFF time.

Action after time Completion, on opposite transition of signal or 
level i.e. if cycles starts on SP then action for ATT is at SA.

Down or Remaining counting selection.

12.’UP’ key short pressed in online edit mode - If both timers are configured then display    
     will show Set value of both the timers for 2 sec. When only one timer is configured then
     it wil have no effect on the screen.
13.’Up/down’ short pressed in Program mode - Increment/ Decrement the value/parameter.
14.’Down + UP’ key long pressed in run mode when both timers are selected - Reset the
     timer1 and timer2 both. 

Key Conventions:

selected). 

play.

3.    Modes can

.

.

Reviews: