background image

5

 

    

ITEM  PART 

DESCRIPTION  

QTY.

08377 

Crankcase 

1

08378 

Oil Fill Plug with Gasket 

1

06479 

Crankcase Cover 

1

3A 

07186 

Oil Sight Glass w/Gasket 

1

08380 

O-Ring 

1

07109 

Oil Drain Plug 

1

5A 06015  O-Ring 

1

5B 

08092 

Plug with Gasket 

1

6 01010  Screw 

4

6A 

01011-0400  Spring Washer 

4

04739 

Bearing Cover, Open 

1

7A 

03266 

Motor Flange 

1

7B 

03297 

Plug, M12 x 1 

1

05291 

Bearing Cover, Closed 

1

8A 

05292 

Shim, 0.1 mm 

1-3

9 01016  O-Ring 

2

10 

07114 

Hexagon Socket Screw 

4

10A 

07774 

Hexagon Socket Screw 

4

11 

07459 

Radial Shaft Seal 

1

12 

05350 

Bearing 

2

13 

03268 

Crankshaft 

1

13A 

04742 

Spacer Ring 

1

14 

03269 

Magnet 

1

15 

08390 

Connecting Rod Assembly  3

15B 

05249 

Connecting Rod Screw 

3

15C 

05348 

Adapter Sleeve 

3

16 

05933 

Plunger Assembly 

3

16A 

05352 

Plunger Base 

3

16B 

06927 

Plunger Pipe 

3

16D 

08399 

Tension Screw 

3

16E 

07023 

O-Ring 

3

P470H PARTS LIST

ITEM  PART 

DESCRIPTION 

QTY.

16F 

07203 

Support Ring 

3

16G 

07258 

Copper Gasket 

3

17 

06790 

Crosshead Pin 

3

19 

08366 

Oil Seal 

3

20 

06928 

Seal Adapter 

3

20A 

08059 

O-Ring 

3

21 

06929 

Seal Case 

3

21A 07150 

O-Ring 

6

22 

06930 

Valve Holder 

3

23 

06931* 

Grooved Seal  

6

24 

06932 

Support Ring 

3

25 

06933 

Intermediate Casing 

1

 

25B 02009 

O-Ring 

2

26 

06935 

Valve Casing 

1

27A 

04365 

Valve Assembly 

6

27 

06937 

Valve Seat 

6

28 

06938 

Valve Plate  

6

29 

06959 

Valve Spring 

6

30 

06939 

Valve Spring Retainer 

6

31 

07212 

O-Ring 

6

32 

08373 

Plug 

3

33 

07214 

O-Ring 

3

34 

06494 

Cap Screw 

8

36 

07703 

Plug, 3/4” BSP 

3

36A 

04529 

Copper Ring 

3

*

Important!  

If the pump is not used for a long period 

of time, it is possible the seals (23) could become hard 

or brittle thus causing the pump to leak when put into 

operation.  If this is the case we recommend these seals 

be replaced every 4 years.

Plunger Packing Kit, #09565

Item  Part # 

Description 

Qty.

20A 

08059 

O-Ring 

3

21A 07150 

O-Ring 

6

23 

06931 

Grooved Seal 

6

24 

06932 

Support Ring 

3

25B 02009 

O-Ring 

2

Valve Assembly Kit, #09566

Item  Part # 

Description 

   Qty.

27A 

04365 

Valve Assembly 

  6

31 

07212 

O-Ring 

  6

33 

07214 

O-Ring 

  3

Oil Seal Kit,  #09306

Item  Part # 

Description 

  Qty.

19 

08366 

Oil Seal 

    3

P470H REPAIR KITS

P470H Torque Specifications

Item

Part #

Description

Lubrication Info

Torque Amount

3A

07186

Oil Sight Glass/Gasket

Loctite 5910

106 in.-lbs. (12 Nm)

5

07109

Plug

59 ft.-lbs. (80 Nm)

5B

08092

Plug w/Gasket

59 ft.-lbs. (80 Nm)

6

01010

Screw

110 in.-lbs. (12.5 Nm)

10

07114

Screw with Washer

132 in.-lbs. (15 Nm)

10A

07774

Hexagon Socket Screw

132 in.-lbs. (15 Nm)

15

08390

Connecting Rod Screw

97 in.-lbs. (11 Nm)

16D

08399

Tension Screw

Loctite 243

21 ft.-lbs. (28 Nm)

32

08373

Plug

Loctite 243

125 ft.-lbs. (170 Nm)

34

06494

Cap Screw

Lightly Oil Threads

30 ft.-lbs. (40 Nm)

Summary of Contents for P470H

Page 1: ...oded View page 4 Parts List Kits page 5 Torque Specifications page 5 Repair Instructions pages 6 7 Dimensions back page Warranty Information back page Triplex Ceramic Plunger Pump Operating Instructions Repair and Service Manual Model P470H Hydraulic Drive Pump Updated 04 22 ...

Page 2: ...e explosive and toxic media the pump manufacturer must be consulted with regard to the resistance of the pump material It is the responsibility of the equipment manufacture and or operator to ensure that all pertinent safety regulations are adhered to Required NPSH refers to water specific weight 1kg dm3 viscosity 1 E and maximum premissible pump revolutions Operation and Maintenance Check oil lev...

Page 3: ...8 7 2 9 7 14 5 19 6 1200 15 2 5 2 7 9 10 5 15 7 21 3 1300 16 5 5 7 8 5 11 4 17 1 23 1 1450 18 4 6 3 9 5 12 7 19 0 25 8 P470 HORSEPOWER REQUIREMENTS NOTE In order to drive the pump from the side opposite the present shaft extension simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position Be certain to rotate the seal case item 20 as well so that the...

Page 4: ...4 Exploded View P470H ...

Page 5: ...asing 1 27A 04365 Valve Assembly 6 27 06937 Valve Seat 6 28 06938 Valve Plate 6 29 06959 Valve Spring 6 30 06939 Valve Spring Retainer 6 31 07212 O Ring 6 32 08373 Plug 3 33 07214 O Ring 3 34 06494 Cap Screw 8 36 07703 Plug 3 4 BSP 3 36A 04529 Copper Ring 3 Important If the pump is not used for a long period of time it is possible the seals 23 could become hard or brittle thus causing the pump to ...

Page 6: ...gs 21A 31 33 Replace worn parts Reassemble in same order Coat new o rings with oil before installation Coat O rings 25B with silicon grease and place them in their re cessses Insert seal cases 21 into valve casing 26 before mounting the whole unit Slide valve casing 26 over plungers Tighten hexagon socket screws 34 crosswise and evenly at 36 ft lbs Tighten plugs 32 at 125 ft lbs 170 Nm lmportant W...

Page 7: ...aring covers 7 8 onto the crankshaft ends Screw on bearing covers with screws 10 Mount connecting rod halves and tighten screws 15 at 22 ft lbs Mount crankcase cover 3 togeth er with O ring 4 Replace seal adaptors 20 seal casing 25 and valve casing 26 Replace eight 8 hexagon screws 34 and tighten to 30 ft lbs 40 Nm 9 Check plunger surfaces 16 Damaged surfaces lead to accelerated seal wear Deposits...

Page 8: ...ications made by the customer or third party 6 The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries Inc Liability under this warranty is on all non wear parts and limited to the replacement or repair of those products returned freight prepaid to Giant Industries which are deemed to be defective due to workmanship or...

Reviews: