background image

3

NOTE:

  In order to drive the pump from the side opposite the present shaft extension, 

simply remove the valve casing from the crankcase and rotate the pumps 180 

degrees to the desired position.  Be certain to rotate the seal case (item #20) as 

well, so that the weep holes are 

down at the six o’clock position.  Exchange the 

oil fill and the oil drain plugs, also.  Refer to the repair instructions as necessary 

for the proper assembly sequence.

HORSEPOWER RATINGS:

The rating shown are the power requirements for the pump.  Gas engine power outputs 

must be approximately twice the pump power requirements shown above.

We recommend a 1.15 service factor be specified when selecting an electric motor as the 

power source. To compute specific pump horsepower requirements, use the following 

formula:  

 

HP = (GPM X PSI) / 1450

Specifications

ModelS P225/P226/P223/P228

Consult the factory for special requirements that must be met if the 

pump is to operate beyond one or more of the limits specified above. 

Max. 

Flow

Max. 

Flow

Nominal/

Intermittent 

Pressure

Nominal/

Intermittent 

Pressure

Max. 

Speed

Max. 

Inlet 

Pressure

Max. 

Inlet 

Pressure

Plunger 

Diameter

Plunger 

Diameter

Stroke Stroke Power 

Req’d

Power 

Req’d

Model GPM l/min

PSI

bar

RPM

PSI

bar

in

mm

in

mm

BHP

kW

P225

0.9

3.4

2000/3000

140/200

1750

145

10

0.63

16

0.13

3.4

1.9

1.4

P226

1.5

5.7

2000/3000

140/200

1750

145

10

0.63

16

0.22

5.5

3.1

2.3

P225

1.6

6.1

2000/3000

140/200

3450

145

10

0.63

16

0.13

3.4

3.3

2.5

P223

1.7

6.4

2000/3000

140/200

1750

145

10

0.63

16

0.25

6.3

3.5

2.6

P228

1.8

6.8

2000/3000

140/200

1750

145

10

0.63

16

0.28

7.0

3.7

2.8

P225

2.8

10.6

2000/3000

140/200

3450

145

10

0.63

16

0.22

5.5

5.8

4.3

P223

3.0

11.4

2000/3000

140/200

3450

145

10

0.63

16

0.25

6.3

6.2

4.6

P228

3.3

12.7

2000/3000

140/200

3450

145

10

0.63

16

0.28

7.0

6.9

5.2

  

 

*

Positive inlet pressure required- Make sure that suction pulsation is sufficiently dampened-water column resonance must be avoided.

Common Specifications     

                    U.S.                                                                           Metric

Max. Temperature of Pumped Fluids .....................160

o

 F .......................................................................70

C

Inlet Ports ....................................................................................................................................

(2) 1/2” BSP

Discharge Ports ...........................................................................................................................

(2) 3/8” BSP

Shaft Rotation ...............................................................................................Top of Pulley Towards Fluid End

Crankshaft Diameter..............................................0.98” ...................................................................... 24 mm

Key Width ..............................................................

0.31”

 ........................................................................ 8 mm

Shaft Mounting ..................................................................................................... Right Side Facing Manifold

Weight ...................................................................11.7 lbs. ..................................................................

5.3 Kg

Crankcase Oil Capacity .........................................

7.5 fl.oz.

 ............................................................ 0.22 Liter

Extended Crankcase Oil Capacity .........................

9.0 fl.oz.

 ............................................................ 0.27 Liter

Volumetric Efficiency @ 1750 RPM

 .......................................................................................................... 0.94

Volumetric Efficiency @ 3450 RPM

 .......................................................................................................... 0.87

Mechanical Efficiency @ 3450 RPM

 ........................................................................................................ 0.86

Summary of Contents for P200A Series Repair and

Page 1: ...228 Series P200A 16mm versions Contents Installation Instructions page 2 Pump Specifications pages 3 Exploded View page 4 Parts List page 5 Kits Torque Specifications page 5 Recommended Spare Parts Li...

Page 2: ...operator to ensure that all pertinent safety regulations are adhered to Required NPSH refers to water specific weight 1kg dm3 viscosity 1 E at maximum permissible revolutions Operation and Maintenanc...

Page 3: ...Plunger Diameter Plunger Diameter Stroke Stroke Power Req d Power Req d Model GPM l min PSI bar RPM PSI bar in mm in mm BHP kW P225 0 9 3 4 2000 3000 140 200 1750 145 10 0 63 16 0 13 3 4 1 9 1 4 P226...

Page 4: ...4 Exploded View P225 P226 P223 P228 Pumps...

Page 5: ...9 07109 Plug 1 2 BSP 1 39A 07661 Seal 1 Spare Parts P225 P226 P223 P228 Pumps ITEM PART NO DESCRIPTION QTY 1 08300 Crankcase 1 2 06773 Oil Dipstick with O Ring 1 3 08302 Crankcase Cover Short 1 3 0830...

Page 6: ...sleeve 23 from the valve cas ing 26 Remove the v sleeve 23A from the seal case 20 Inspect all parts including o ring 21 for wear and re place as necessary 8 Check surfaces of plunger 16 A dam aged sur...

Page 7: ...P225 P226 P223 P228 PUMPS NOTE Contact Giant Industries for Service School Information Phone 419 531 4600 NOTE If there are deposits of any kind i e lime deposits in the valve casing be certain that t...

Page 8: ...tomer or third party 6 Theoperationofpumpsandoraccessoriesexceedingthespecificationssetforth in the Operations Manuals provided by Giant Industries Inc Liability under this warranty is on all non wear...

Reviews: